首页> 外文期刊>Journal of building performance simulation >Simplified transient thermal model for integrated structures of solar collector with building envelope
【24h】

Simplified transient thermal model for integrated structures of solar collector with building envelope

机译:带有建筑围护结构的集热器集成结构的简化瞬态热模型

获取原文
获取原文并翻译 | 示例

摘要

Building integrated solar thermal (BIST) systems have attracted more and more attention in researches and applications. The transient thermal performance of BIST components is different from separate solar collectors and building envelopes (walls or roofs). This paper proposed a simplified transient thermal model for integrated structure of flat plate solar collector with building envelope. The simplified model takes the absorber plate as the interface, the integrated structure is divided into top part and back part by the interface, the absorber plate temperature is calculated without consideration heat capacitance of the wall and taken as the input to calculate heat transfer through the wall by response factor method. The calculated results by the simplified model agreed well with the state space model under various conditions, suggesting the simplified model is valid. The analysis of heat transfer through the top part is further simplified and influence of simplification is discussed.
机译:建筑物集成太阳能热(BIST)系统在研究和应用中已引起越来越多的关注。 BIST组件的瞬态热性能不同于单独的太阳能收集器和建筑物围护结构(墙壁或屋顶)。针对建筑围护结构平板太阳能集热器的整体结构,提出了一种简化的瞬态热模型。简化模型以吸收板为界面,通过接口将集成结构分为顶部和背面,吸收板温度的计算不考虑壁的热容,并作为输入来计算通过板的传热。墙通过响应因子法。在各种条件下,简化模型的计算结果与状态空间模型吻合得很好,说明简化模型是有效的。进一步简化了通过顶部的传热分析,并讨论了简化的影响。