Sensitivity of Joint Kinematics and Kinetics to Different Pose Estimation Algorithms and Joint Constraints in the Elderly

机译:关节运动学和动力学对老年人不同姿势估计算法和关节约束的敏感性

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this research was to study the sensitivity of lower limb joint kinematics and kinetics, calculated during different functional tasks (walking, stair descent and stair ascent) in a sample of older adults, to different pose estimation algorithms and models' joint constraints. Three models were developed and optimized differently: in one model, each segment had 6 degrees of freedom (segment optimization, SO), while in the other two, global optimization (GO) was used, with different joint constraints: (1) GO, allowing all joint rotations; (2) GOR, allowing three rotations at the hip, one at the knee (flexion/extension) and two at the ankle (dorsi/plantar flexion and eversion/inversion). The results showed that joint angles are more sensitive to the model's constraints than joint moments and, the more restrictive the model, the higher the differences between models, especially for the frontal and transverse planes (max. RMS difference during gait: 11.7 degrees (64%) vs 0.12 N•m/kg (35.4%). In addition, except for knee abduction/adduction angle, differences between SO and GO models were relatively low. Since GO avoids the nonanatomical dislocations sometimes observed in SO, choosing this model seems to be reasonable for future studies with a similar sample and study design.
机译:这项研究的目的是研究在老年人样本中的不同功能任务(步行,楼梯下降和楼梯上升)期间计算出的下肢关节运动学和动力学对不同姿势估计算法和模型关节约束的敏感性。三种模型的开发和优化方式不同:在一个模型中,每个网段都有6个自由度(分段优化,SO),而在另外两个模型中,则使用了全局优化(GO),但联合约束不同:(1)GO,允许所有关节旋转; (2)GOR,允许在髋部旋转三圈,在膝盖旋转一圈(屈曲/伸展),在踝部旋转两次(背屈/ plant屈和外翻/倒立)。结果表明,关节角度比关节力矩对模型的约束更敏感,并且模型越受约束,模型之间的差异就越大,尤其是对于正面和横向平面(步态时最大RMS差异:11.7度(64) %)vs. 0.12 N•m / kg(35.4%)。另外,除了膝外展/内收角外,SO和GO模型之间的差异相对较小,由于GO避免了有时在SO中观察到的非解剖性脱位,因此选择此模型似乎对于具有类似样本和研究设计的未来研究是合理的。

著录项

  • 来源
    《Journal of Applied Biomechanics》 |2014年第3期|446-460|共15页
  • 作者单位

    LBMF, CIPER, Faculdade de Motricidade Humana, Universidade de Lisboa, Estrada da Costa, 1499-002, Cruz Quebrada, Dafundo, Portugal;

    LBMF, CIPER, Faculdade de Motricidade Humana, Universidade de Lisboa, Estrada da Costa, 1499-002, Cruz Quebrada, Dafundo, Portugal;

    LBMF, CIPER, Faculdade de Motricidade Humana, Universidade de Lisboa, Estrada da Costa, 1499-002, Cruz Quebrada, Dafundo, Portugal;

    LBMF, CIPER, Faculdade de Motricidade Humana, Universidade de Lisboa, Estrada da Costa, 1499-002, Cruz Quebrada, Dafundo, Portugal;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    modeling; optimization; degrees of freedom; soft tissue artifact; locomotion;

    机译:造型;优化;自由程度;软组织伪影;运动;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号