首页> 外文期刊>Journal of the American Oil Chemists' Society >A new method for determining aflatoxins in groundnut and groundnut cake using fourier transform infrared spectroscopy with attenuated total reflectance
【24h】

A new method for determining aflatoxins in groundnut and groundnut cake using fourier transform infrared spectroscopy with attenuated total reflectance

机译:衰减全反射的傅立叶变换红外光谱法测定花生和花生饼中黄曲霉毒素的新方法

获取原文
获取原文并翻译 | 示例
           

摘要

A new analytical method was developed for the determination of aflatoxins in groundnut and groundnut cakes by Fourier transform infrared (FTIR) spectroscopy using horizontal attenuated total reflectance technique. Groundnut and groundnut cake samples were used in this study. The wave-lengths were selected for the four types of aflatoxins—B1, B2, G1, and G2—and the standards prepared for earch by spiking some clean sample with the aflatoxins in concentrations of 0–1200 parts per billion. A partial least square regression was used to derive the calibration models for each toxin. The coefficients of determination (R 2) of the calibration model were computed for the FTIR spectroscopy predicted values vs. actual values of aflatoxins in parts per billion. The R 2 was found to be 0.9911, 0.9859, 0.9986, and 0.9789 for aflatoxins B1, B2, G1 and G2, respectively. Standard errors of calibration for groundnut samples were found to be 1.80, 2.03, 1.42, and 2.05 for aflatoxins B1, B2, G1, and G2, respectively. Calibration models were validated with an independent set of samples. The R 2 of validation models were computed. The SD of the difference for repeatability of the FTIR method was found to be better than that of the chemical method. Based on the results obtained, FTIR spectroscopy can be a useful instrumental method for determining aflatoxins in oilseeds and oilseed cakes. With its speed and ease of data manipulation by computer software, it is a possible alternative to the standard wet chemical methods for a rapid and accurate routine determination of aflatoxin levels in food and feed.
机译:开发了一种新的分析方法,该方法使用水平衰减全反射技术通过傅里叶变换红外光谱(FTIR)光谱法测定花生和花生饼中的黄曲霉毒素。本研究使用花生和花生饼样品。为四种黄曲霉毒素(B1 ,B2 ,G1 和G2 )选择了波长,并通过添加一些干净的样品并准备了标准品以供搜寻黄曲霉毒素的浓度为0-1.200十亿份。使用偏最小二乘回归法得出每种毒素的校准模型。计算FTIR光谱预测值与黄曲霉毒素实际值(十亿分之一)的校准模型的确定系数(R 2 )。黄曲霉毒素B1 ,B2 ,G1 和G2 的R 2 分别为0.9911、0.9859、0.9986和0.9789。对于黄曲霉毒素B1 ,B2 ,G1 和G2 ,花生样品的校准标准误差分别为1.80、2.03、1.42和2.05。校准模型由一组独立的样本验证。计算了验证模型的R 2 。发现FTIR方法的重复性差异的SD优于化学方法。基于获得的结果,FTIR光谱法可用于测定油料种子和油料饼中的黄曲霉毒素。凭借其快速和易于通过计算机软件进行数据处理的功能,它可以替代标准的湿化学方法,从而快速,准确地常规测定食品和饲料中的黄曲霉毒素水平。

著录项

  • 来源
    《Journal of the American Oil Chemists' Society》 |2001年第10期|985-992|共8页
  • 作者单位

    Department of Food Technology Faculty of Food Science and Biotechnology Universiti Putra Malaysia;

    Department of Food Technology Faculty of Food Science and Biotechnology Universiti Putra Malaysia;

    Department of Food Science Faculty of Food Science and Biotechnology Universiti Putra Malaysia;

    Department of Food Technology Faculty of Food Science and Biotechnology Universiti Putra Malaysia;

    Department of Food Technology Faculty of Food Science and Biotechnology Universiti Putra Malaysia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Aflatoxin; ATR; FTIR; groundnut; PLS;

    机译:黄曲霉毒素;ATR;FTIR;花生;PLS;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号