首页> 外文期刊>The International Journal of Cardiovascular Imaging >Doppler tissue imaging and catheter-derived measures are not independent predictors of rejection in pediatric heart transplant recipients
【24h】

Doppler tissue imaging and catheter-derived measures are not independent predictors of rejection in pediatric heart transplant recipients

机译:多普勒组织成像和导管测量不是小儿心脏移植受者排斥反应的独立预测因子

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of the study is to determine the association of Doppler Tissue Imaging (DTI) and catheter-derived measures with rejection in pediatric heart transplant (PHT) recipients and to determine any correlation between DTI and catheter-derived measurements. Sixty echocardiograms were prospectively performed in 37 PHT recipients at the time of surveillance cardiac biopsy. During right-heart cardiac catheterization, sequential pressures of the right heart and pulmonary capillary wedge pressures (PCWP) were measured. DTI was performed to obtain peak systolic (S’), early (E’) and late (A’) diastolic velocities (cm/s) at tricuspid annulus, septum and mitral annulus. Septal S’ and tricuspid annular A’ were associated with rejection, but had low sensitivity and specificity. Elevated lateral mitral E/E’ did not predict rejection. The mean pulmonary capillary wedge pressure (PCWP) and cardiac index were similar in those with and without rejection. The lateral mitral and septal E/E’ did not correlate with PCWP. Some DTI-derived measures were altered during rejection, but were not clinically useful predictors of rejection. Catheter-derived measures were not significantly altered during rejection and did not correlate with DTI-derived measures. None of these measures can replace the current practice of performing cardiac biopsy for surveillance of rejection.
机译:这项研究的目的是确定多普勒组织成像(DTI)和导管衍生的措施与小儿心脏移植(PHT)受者排斥反应的关系,并确定DTI和导管衍生的测量之间的任何相关性。在监测心脏活检时,对37名PHT接受者进行了60次超声心动图检查。在右心导管检查期间,测量了右心的顺序压力和肺毛细血管楔压(PCWP)。进行DTI检查可得出三尖瓣环,间隔和二尖瓣环的收缩期峰值(S’),早期(E’)和晚期(A’)舒张速度(cm / s)。间隔S’和三尖瓣环A’与排斥反应相关,但敏感性和特异性较低。二尖瓣外侧E / E'升高不能预测排斥反应。有排斥反应者和无排斥反应者的平均肺毛细血管楔压(PCWP)和心脏指数相似。二尖瓣外侧和中隔E / E’与PCWP不相关。一些DTI衍生的措施在排斥反应中发生了变化,但并不是排斥反应的临床有用预测指标。在排斥过程中,导管衍生的测量没有显着改变,并且与DTI衍生的测量没有关联。这些措施都不能代替目前进行心脏活检以监测排斥反应的做法。

著录项

  • 来源
  • 作者单位

    Department of Pediatrics Division of Pediatric Cardiology Arkansas Children’s Hospital and University of Arkansas for Medical Sciences Little Rock AR USA;

    Department of Pediatrics Division of Pediatric Cardiology Arkansas Children’s Hospital and University of Arkansas for Medical Sciences Little Rock AR USA;

    Department of Pediatrics Division of Pediatric Cardiology Arkansas Children’s Hospital and University of Arkansas for Medical Sciences Little Rock AR USA;

    Department of Pediatrics Division of Pediatric Cardiology Arkansas Children’s Hospital and University of Arkansas for Medical Sciences Little Rock AR USA;

    Arkansas Center for Birth Defects Research and Prevention Arkansas Children’s Hospital and University of Arkansas for Medical Sciences Little Rock AR USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Doppler tissue imaging; Pediatric heart transplant; Rejection; Catheterization;

    机译:多普勒组织成像;小儿心脏移植;排斥反应;导尿;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号