首页> 外文期刊>IEEE Transactions on Instrumentation and Measurement >A broadband power meter calibration system in the frequency range from 10 MHz to 40 GHz using a coaxial calorimeter
【24h】

A broadband power meter calibration system in the frequency range from 10 MHz to 40 GHz using a coaxial calorimeter

机译:使用同轴量热仪在10 MHz至40 GHz频率范围内的宽带功率计校准系统

获取原文
获取原文并翻译 | 示例

摘要

A broadband power meter calibration system based on a newly constructed coaxial calorimeter has been developed in the frequency region 10 MHz-40 GHz. The RF power is measured as the difference of DC power supplied to the calorimeter built-in heater in the RF load, when RF is turned off and on, holding an isothermal control between the RF load and a temperature reference. To minimize the error due to the adiabatic coaxial waveguide, we devised a new method utilizing its output port as a test port. The evaluations showed a calibration uncertainty of (0.28-2.2)% expressed by one standard deviation at the 1 mW level in the full band.
机译:已经在10 MHz-40 GHz的频率范围内开发了基于新型同轴量热仪的宽带功率计校准系统。在关闭和打开RF并保持RF负载与温度参考之间的等温控制的情况下,RF功率的测量值是在RF负载中提供给热量计内置加热器的DC电源的差值。为了最小化绝热同轴波导引起的误差,我们设计了一种新方法,将其输出端口用作测试端口。评估显示,在整个频带中,以1 mW的水平通过一个标准偏差表示的校准不确定度为(0.28-2.2)%。