首页> 外文期刊>IEICE Transactions on Fundamentals of Electronics, Communications and Computer Sciences >Correction Of Overlapping Template Matching Test Included In Nist Randomness Test Suite
【24h】

Correction Of Overlapping Template Matching Test Included In Nist Randomness Test Suite

机译:Nist随机性测试套件中包含的重叠模板匹配测试的更正

获取原文
获取原文并翻译 | 示例

摘要

Accurate values for occurrence probabilities of the template used in the overlapping template matching test included in NIST randomness test suite (NIST SP800-22) have been analyzed. The inaccurate values used in the NIST randomness test suite cause significant difference of pass rate. When the inaccurate values are used and significance level is set to 1%, the experimental mean value of pass rate, which is calculated by use of random number sequences taken from DES (Data Encryption Standard), is about 98.8%. In contrast, our new values derived from a set of recurrence formulas for the NIST randomness test suite give an empirical distribution of pass rate that meets the theoretical binomial distribution. Here, the experimental mean value of pass rate is about 99%, which corresponds to the significance level 1%.
机译:已分析了NIST随机性测试套件(NIST SP800-22)中包含的重叠模板匹配测试中使用的模板的出现概率的准确值。 NIST随机性测试套件中使用的不正确值会导致合格率显着不同。当使用不正确的值并且将显着性水平设置为1%时,通过使用从DES(数据加密标准)获得的随机数序列计算得出的通过率的实验平均值约为98.8%。相反,我们从NIST随机性测试套件的一组递归公式得出的新值给出了符合理论二项式分布的合格率的经验分布。在这里,通过率的实验平均值约为99%,对应于显着性水平1%。