High-frequency transducers, up to 35-50 MHz, are widely used in ophthalmic echography to image fine eye structures. Phased-array techniques are not practically applicable at such a high frequency, due to the too small size required for the single transducer element, and mechanical scanning is the only practical alternative. At present, all ophthalmic ultrasound systems use focused single-element, mechanically scanned probes. A good probe positioning and image evaluation feedback requires an image refresh-rate of about 15-30 frames per second, which is achieved in commercial mechanical scanning probes by using electromagnetic motors. In this work, we report the design, construction, and experimental characterization of the first mechanical scanning probe for ophthalmic echography based on a small piezoelectric ultrasound motor. The prototype probe reaches a scanning rate of 15 sectors per second, with very silent operation and little weight. The first high-frequency echographic images obtained with the prototype probe are presented.
机译:高达35-50 MHz的高频换能器被广泛用于眼科回波描记术中,以成像精细的眼睛结构。由于单个换能器元件所需的尺寸太小,相控阵技术在如此高的频率上实际上不适用,并且机械扫描是唯一可行的选择。当前,所有眼科超声系统都使用聚焦的单元素机械扫描探头。良好的探头定位和图像评估反馈需要每秒约15-30帧的图像刷新率,这是在商用机械扫描探头中通过使用电磁马达实现的。在这项工作中,我们报告了第一个基于小型压电超声马达的眼动回波描记器机械扫描探头的设计,构造和实验特性。原型探针的扫描速度达到每秒15个扇区,操作非常安静且重量轻。展示了使用原型探头获得的第一张高频回波图像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号