An Improved Pulse Density Modulation Strategy Based on Harmonics for ICPT System

机译:基于ICPT系统谐波的改进脉冲密度调制策略

获取原文
获取原文并翻译 | 示例

摘要

To improve the efficiency of high frequency inverter (HFI) in inductively coupled power transfer system, pulse density modulation (PDM) is often used. However, the output current of the HFI fluctuates seriously, especially at light load. It affects the stable operation of the system and the implementation of zero voltage switching. In this article, an improved pulse density modulation (IPDM) is proposed to reduce current fluctuation. It applies harmonics pulse to replace the fundamental pulse and zero state, and evenly distributes the switching sequence to reduce current fluctuation. Simultaneously, the best phase-shift angle of harmonics is obtained by using the transient analysis method to further reduce the output current fluctuation. The IPDM current fluctuation is less than PDM and the efficiency become higher at light load by the theoretical analysis, while PDM is better at heavy load. So, a hybrid modulation strategy is applied that IPDM and PDM are used for light and heavy load, respectively. The experimental results show that the HFI output current ripple coefficient is reduced by 15% to 62% and the efficiency is improved at light load.
机译:为了提高电感耦合电力传输系统中高频逆变器(HFI)的效率,通常使用脉冲密度调制(PDM)。然而,HFI的输出电流严重波动,特别是在轻负载下。它影响系统的稳定运行和零电压切换的实现。在本文中,提出了一种改进的脉冲密度调制(IPDM)以降低电流波动。它适用谐波脉冲来替换基本脉冲和零状态,均匀分布切换顺序以降低电流波动。同时,通过使用瞬态分析方法来进一步降低输出电流波动来获得谐波的最佳相移角。 IPDM电流波动小于PDM,通过理论分析,效率变得更高,而PDM在重载中更好。因此,应用混合调制策略,即IPDM和PDM分别用于光和重载。实验结果表明,HFI输出电流纹波系数减少了15%至62%,效率在轻载下得到改善。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号