首页> 外文期刊>IEEE Transactions on Circuits and Systems. 1 >The study of the relation between R/sub n/-G/sub n/ noise model and E/sub n/-I/sub n/ noise model of an amplifier
【24h】

The study of the relation between R/sub n/-G/sub n/ noise model and E/sub n/-I/sub n/ noise model of an amplifier

机译:研究放大​​器的R / sub n / -G / sub n /噪声模型与E / sub n / -I / sub n /噪声模型之间的关系

获取原文
获取原文并翻译 | 示例

摘要

The R/sub n/-G/sub n/ noise model can only be used in the case of microwave low-noise amplifier design. Its application scopes are limited and in particular, it cannot be used in low-frequency low-noise amplifier design. This paper has adopted the E/sub n/-I/sub n/ noise model with spectral correlative coefficient (SCC) so that it can be used not only in high-frequency and narrow-band, but also in low frequency, source reactance, and wide-band amplifier low-noise design. In this paper, the equivalent relation between the E/sub n/-I/sub n/ noise model and the R/sub n/-G/sub n/, noise model is derived, and the measurement method of the E/sub n/-I/sub n/ noise model parameters and the measurement results are given. The R/sub n/-G/sub n/, noise model parameters can be accurately obtained by use of the equivalent relation.
机译:R / sub n / -G / sub n /噪声模型仅可用于微波低噪声放大器设计。它的应用范围有限,特别是不能用于低频低噪声放大器设计中。本文采用了具有频谱相关系数(SCC)的E / sub n / -I / sub n /噪声模型,因此它不仅可以用于高频和窄带,还可以用于低频,电抗,以及宽带放大器的低噪声设计。本文推导了E / sub n / -I / sub n /噪声模型与R / sub n / -G / sub n /噪声模型之间的等效关系,并给出了E / sub的测量方法给出了n / -I / sub n /噪声模型参数和测量结果。 R / sub n / -G / sub n /噪声模型参数可以通过使用等效关系来精确获得。