首页> 外文期刊>IEEE transactions on circuits and systems . I , Regular papers >Switched-Capacitor Track-and-Hold Amplifiers With Low Sensitivity to Op-Amp Imperfections
【24h】

Switched-Capacitor Track-and-Hold Amplifiers With Low Sensitivity to Op-Amp Imperfections

机译:对运算放大器缺陷具有低灵敏度的开关电容器跟踪和保持放大器

获取原文
获取原文并翻译 | 示例

摘要

This paper describes high-precision switched-capacitor (SC) track-and-hold amplifier (THA) stages. They use a novel continuous-time correlated double sampling (CDS) scheme to desensitize the operation to amplifier imperfections. Unlike earlier predictive-CDS amplifiers, the circuits do not need a sampled-and-held input signal for their operation. During the tracking period, an auxiliary continuous-time signal path is established, which predicts the output voltage during the holding period. This allows accurate operation even for low amplifier gains and large offsets over a wide input frequency range. Extensive simulations were performed to compare the performance of the proposed THAs with earlier circuits utilizing CDS. The results verify that their operation is far more robust than that of any previously described SC amplifiers
机译:本文介绍了高精度开关电容器(SC)采样保持放大器(THA)阶段。他们使用一种新颖的连续时间相关双采样(CDS)方案来降低对放大器缺陷的敏感性。与早期的预测CDS放大器不同,这些电路不需要采样保持输入信号即可工作。在跟踪周期内,建立了一个辅助连续时间信号路径,该路径可预测保持周期内的输出电压。即使在很宽的输入频率范围内,即使放大器增益较低且失调较大,也可实现准确的操作。进行了广泛的仿真,以将拟议的THA与采用CDS的早期电路的性能进行比较。结果证明,它们的操作远比之前描述的任何SC放大器都要强大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com