首页> 外文期刊>IEEE transactions on biomedical circuits and systems >Multi-Frequency Electrical Impedance Tomography System With Automatic Self-Calibration for Long-Term Monitoring
【24h】

Multi-Frequency Electrical Impedance Tomography System With Automatic Self-Calibration for Long-Term Monitoring

机译:具有自动自校准功能的多频电阻抗层析成像系统,可进行长期监测

获取原文
获取原文并翻译 | 示例

摘要

Electrical Impedance Tomography (EIT) is a safe medical imaging technology, requiring no ionizing or heating radiation, as opposed to most other imaging modalities. This has led to a clinical interest in its use for long-term monitoring, possibly at the bedside, for ventilation monitoring, bleeding detection, gastric emptying and epilepsy foci diagnosis. These long-term applications demand auto-calibration and high stability over long time periods. To address this need we have developed a new multi-frequency EIT system called the KHU Mark2.5 with automatic self-calibration and cooperation with other devices via a timing signal for synchronization with other medical instruments. The impedance measurement module (IMM) for flexible configuration as a key component includes an independent constant current source, an independent differential voltmeter, and a current source calibrator, which allows automatic self-calibration of the current source within each IMM. We installed a resistor phantom inside the KHU Mark2.5 EIT system for intra-channel and inter-channel calibrations of all voltmeters in multiple IMMs. We show the deterioration of performance of an EIT system over time and the improvement due to automatic self-calibration. The system is able to maintain SNR of 80 dB for frequencies up to 250 kHz and below 0.5% reciprocity error over continuous operation for 24 hours. Automatic calibration at least every 3 days is shown to maintain SNR above 75 dB and reciprocity error below 0.7% over 7 days at 1 kHz. A clear degradation in performance results with increasing time between automatic calibrations allowing the tailoring of calibration to suit the performance requirements of each application.
机译:电阻层析成像(EIT)是一种安全的医学成像技术,与大多数其他成像方式相比,它不需要电离或加热辐射。这引起了对其在长期监测中(可能在床边)用于通气监测,出血检测,胃排空和癫痫灶诊断的临床兴趣。这些长期应用需要长时间自动校准和高稳定性。为了满足这一需求,我们开发了一种称为KHU Mark2.5的新型多频EIT系统,该系统具有自动自校准功能,并通过与其他医疗器械同步的定时信号与其他设备协作。灵活配置的阻抗测量模块(IMM)作为关键组件,包括一个独立的恒定电流源,一个独立的差动电压表和一个电流源校准器,该模块允许自动自校准每个IMM中的电流源。我们在KHU Mark2.5 EIT系统内部安装了一个电阻体模,用于在多个IMM中对所有电压表进行通道内和通道间校准。我们显示了随着时间的推移EIT系统性能的下降以及由于自动自校准带来的改善。该系统在24小时连续运行的情况下,对于高达250 kHz的频率和低于0.5%的互易误差,能够保持80 dB的SNR。自动校准至少每3天显示一次,可在1 kHz的7天内保持SNR高于75 dB,互易误差低于0.7%。随着自动校准之间时间的增加,会导致性能明显下降,从而可以定制校准以适合每种应用程序的性能要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号