首页> 外文期刊>IEE Proceedings. Part A >Sparkover in the rod-plane gap under composite slow front positive impulse/alternating voltages
【24h】

Sparkover in the rod-plane gap under composite slow front positive impulse/alternating voltages

机译:复合慢前正脉冲/交流电压下杆面间隙中的火花放电

获取原文
获取原文并翻译 | 示例

摘要

Problems are discussed which relate to the measurement of the sparkover voltage of an airgap under a composite voltage comprising an impulse superimposed on an alternating voltage. The rod-plane gap has been taken as an example. Sparkover values have been measured with the impulse generator fired at angles 0, 90, 180 and 270 in the alternating cycle. Tests have also been made with firing at random angles. Sparkover voltages do not differ significantly from those for simple impulse alone, except for the case of random firing, where a small apparent increase occurs. It is shown that the 'up and down' method of measurement is satisfactory where specific firing angles are used, but is unsatisfactory and misleading where firing is at random angles.
机译:讨论了与在包括叠加在交流电压上的脉冲的复合电压下测量气隙的跳火电压有关的问题。以杆平面间隙为例。在交替循环中,脉冲发生器以角度0、90、180和270点火时,测量了闪络值。还进行了以任意角度发射的测试。火花放电电压与单独的简单脉冲没有明显的不同,除了随机点火的情况外,在随机点火的情况下会出现很小的表观增加。结果表明,“向上和向下”的测量方法在使用特定的发射角度时是令人满意的,但是在以任意角度发射时,则不能令人满意且具有误导性。