Wendelstein 7-X (W7‐X) is the world’s largest superconducting nuclear fusion experiment of the optimized stellarator type. In the first Operation Phase (OP1.1) helium and hydrogen plasmas were studied in limiter configuration. The heating energy was limited to 4 MJ and the main purpose of that campaign was the integral commissioning of the machine and diagnostics, which was achieved very successfully. Already from the beginning a comprehensive set of diagnostics was available to study the plasma. On the path towards high-power, high-performance plasmas, W7‐X will be stepwise upgraded from an inertially cooled (OP1.2, limited to 80 MJ) to an actively cooled island divertor (OP2, 10 MW steady-state plasma operation). The machine is prepared for OP1.2 with 10 inertially cooled divertor units, and the experimental campaign has started recently.The paper describes a subset of diagnostics which will be available for OP1.2 to study the plasma edge, divertor and scrape-off layer physics including those already available for OP1.1, plus modifications, upgrades and new systems. The focus of this summary will be on technical and engineering aspects, like feasibility and assembly but also on reliability, thermal loads and shielding against magnetic fields.
机译:Wendelstein 7-X(W7-X)是世界上最大的优化恒星类型超导核聚变实验。在第一个操作阶段(OP1.1)中,以限制器配置研究了氦和氢等离子体。加热能量限制为4 MJ,该运动的主要目的是对机器和诊断程序进行整体调试,并取得了非常成功的成就。从一开始就已经有一套全面的诊断方法可用于研究血浆。在迈向大功率,高性能等离子的道路上,W7-X将逐步从惯性冷却(OP1.2,限制为80 MJ)升级为主动冷却的岛式偏滤器(OP2,10 MW稳态等离子运行) )。该机器为OP1.2配备了10个惯性冷却的偏滤器单元,最近开始了实验。本文介绍了一些诊断子集,这些内容可用于OP1.2来研究等离子体边缘,偏滤器和刮除层。物理,包括OP1.1已经可用的物理,以及修改,升级和新系统。本摘要的重点将放在技术和工程方面,例如可行性和组装性,还放在可靠性,热负荷和磁场屏蔽方面。

著录项

  • 来源
    《Fusion Engineering and Design》 |2018年第ptaa期|304-308|共5页
  • 作者单位

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Wigner RCP RMI;

    Department of Engineering Physics, University of Wisconsin;

    Max-Planck-Institut für Plasmaphysik;

    Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung - Plasmaphysik;

    Commissariat à l´Energie Atomique DRF/IRFM;

    Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung - Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Department of Engineering Physics, University of Wisconsin;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    University of Auburn;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Oak Ridge National Laboratory;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung - Plasmaphysik;

    Wigner RCP RMI;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Department of Engineering Physics, University of Wisconsin;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung - Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung - Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Department of Engineering Physics, University of Wisconsin;

    Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung - Plasmaphysik;

    Max-Planck-Institut für Plasmaphysik;

    Department of Engineering Physics, University of Wisconsin;

    Wigner RCP RMI;

    Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung - Plasmaphysik;

    Wigner RCP RMI;

    Max-Planck-Institut für Plasmaphysik;

    Los Alamos National Laboratory;

    Wigner RCP RMI;

    Max-Planck-Institut für Plasmaphysik;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Wendelstein 7-X; Diagnostics; Plasma edge; SOL; Steady-state operation;

    机译:Wendelstein 7-X;诊断;等离子边缘;SOL;稳态操作;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号