...
首页> 外文期刊>Food Analytical Methods >Potential Use of FTIR-ATR Spectroscopic Method for Determination of Virgin Coconut Oil and Extra Virgin Olive Oil in Ternary Mixture Systems
【24h】

Potential Use of FTIR-ATR Spectroscopic Method for Determination of Virgin Coconut Oil and Extra Virgin Olive Oil in Ternary Mixture Systems

机译:FTIR-ATR光谱法在三元混合物系统中测定初榨椰子油和特级初榨橄榄油的潜在用途

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The aim of this study was to investigate the feasibility of Fourier-transform infrared (FTIR) spectroscopy combined with multivariate calibrations of partial least square (PLS) and principle component regression (PCR) for analysis of virgin coconut oil (VCO) in the ternary mixture with palm oil (PO) and olive oil, and for analysis of extra virgin olive oil (EVOO) mixed with soybean oil (SO) and corn oil (CO). The spectra of individual oils and their blends with certain concentrations were scanned using horizontal attenuated total reflectance accessory at mid-infrared region of 4,000–650 cm−1. The optimal frequency regions selected for calibration models were based on its ability to give the highest values of coefficient of determination (R 2) and the lowest values of root mean standard error of calibration (RMSEC). PLS was slightly better for quantitative analysis of VCO and EVOO compared with PCR. VCO in ternary mixtures is successfully determined at frequency region of 1,200–1,000 using second derivative FTIR spectra with R 2 and RMSEC values of 0.999 and 0.200, respectively. Meanwhile, EVOO is best determined at 1,200–1,000 using first derivative FTIR spectra with R 2 and RMSEC values of 0.999 and 0.975, respectively. The results showed that FTIR spectroscopy offers accurate and reliable technique for quantitative analysis of VCO and EVOO in ternary systems. In addition, the developed method can be used for the monitoring of VCO and EVOO adulteration with cheaper oils like PO in VCO as well as SO and CO in EVOO.
机译:这项研究的目的是研究傅里叶变换红外(FTIR)光谱结合偏最小二乘(PLS)和主成分回归(PCR)多元变量分析三元混合物中原始椰子油(VCO)的可行性棕榈油(PO)和橄榄油,以及用于分析与大豆油(SO)和玉米油(CO)混合的特级初榨橄榄油(EVOO)的分析。使用水平衰减的全反射附件在4,000–650 cm -1 的中红外区域扫描特定浓度的油及其混合物的光谱。为校准模型选择的最佳频率区域是基于其给出最高确定系数值(R 2 )和最低均方根标准校正误差(RMSEC)的能力。与PCR相比,PLS对VCO和EVOO的定量分析略好。使用R 2 和RMSEC值分别为0.999和0.200的二阶FTIR光谱成功地在1,200–1,000的频率范围内确定了三元混合物中的VCO。同时,最好使用R 2 和RMSEC值分别为0.999和0.975的一阶FTIR光谱将EVOO确定在1,200–1,000。结果表明,FTIR光谱学为三元系统中VCO和EVOO的定量分析提供了准确可靠的技术。此外,开发的方法还可用于监测VCO和EVOO中的掺假情况,其中可使用VCO中的PO以及EVOO中的SO和CO等廉价油。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号