A sensitive and selective isotope dilution ion chromatography/tandem mass spectrometry (ID IC-MS/MS) method was developed and validated for the determination of perchlorate in infant formula. The perchlorate was extracted from infant formula by using 20 ml of methanol and 5 ml of 1 % acetic acid. All samples were spiked with ~(18)O_4 isotope-labelled perchlorate internal standard prior to extraction. After purification on a graphitised carbon solid-phase extraction column, the extracts were injected into an ion chromatography system equipped with an Ionpac AS20 column for separation of perchlorate from other anions. The presence of perchlorate in samples was quantified by isotope dilution mass spectrometry. Analysis of both perchlorate and its isotope-labelled internal standard was carried out on a Waters Quattro Ultima triple quadrupole mass spectrometer operating in a multiple reaction monitoring (MRM) negative ionisation mode. The method was validated for linearity and range, accuracy, precision, sensitivity, and matrix effects. The limit of quantification (LOQ) was 0.4 μgl~(-1) for liquid infant formula and 0.95μgkg~(-1) for powdered infant formula. The recovery ranged from 94% to 110% with an average of 98%. This method was used to analyse 39 infant formula, and perchlorate concentrations ranging from
机译:建立了灵敏且选择性的同位素稀释离子色谱/串联质谱(ID IC-MS / MS)方法,并验证了该方法可用于婴儿配方食品中高氯酸盐的测定。通过使用20 ml甲醇和5 ml 1%乙酸从婴儿配方食品中提取高氯酸盐。在萃取之前,所有样品均用〜(18)O_4同位素标记的高氯酸盐内标加标。在石墨化的碳固相萃取柱上纯化后,将萃取液注入装有Ionpac AS20色谱柱的离子色谱系统中,以从其他阴离子中分离出高氯酸盐。样品中高氯酸盐的存在通过同位素稀释质谱法定量。高氯酸盐及其同位素标记的内标物的分析均在Waters Quattro Ultima三重四极杆质谱仪上进行,该质谱仪以多反应监测(MRM)负电离模式运行。验证了该方法的线性和范围,准确性,精密度,灵敏度和基质效应。液态婴儿配方食品的定量限(LOQ)为0.4μgl〜(-1),粉状婴儿配方食品的定量限为0.95μgkg〜(-1)。回收率从94%到110%不等,平均为98%。该方法用于分析39种婴儿配方食品,高氯酸盐浓度范围从

著录项

  • 来源
    《Food Additives & Contaminants》 |2011年第6期|p.799-806|共8页
  • 作者单位

    Food Research Division, Banting Research Center 2203D, Health Canada, Ottawa, ON K1A 0L2, Canada;

    Food Research Division, Banting Research Center 2203D, Health Canada, Ottawa, ON K1A 0L2, Canada;

    Food Research Division, Banting Research Center 2203D, Health Canada, Ottawa, ON K1A 0L2, Canada;

    Food Research Division, Banting Research Center 2203D, Health Canada, Ottawa, ON K1A 0L2, Canada;

    Food Research Division, Banting Research Center 2203D, Health Canada, Ottawa, ON K1A 0L2, Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    liquid chromatography/mass spectrometry (LC/MS); in-house validation; survey; environmental contaminants; infant formulae;