...
首页> 外文期刊>Food additives & contaminants >Effects of different extraction buffers on peanut protein detectability and lateral flow device (LFD) performance
【24h】

Effects of different extraction buffers on peanut protein detectability and lateral flow device (LFD) performance

机译:不同提取缓冲液对花生蛋白检测能力和侧向流动装置(LFD)性能的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The accidental uptake of peanuts can cause severe health reactions in allergic individuals. Reliable determination of traces of peanuts in food products is required to support correct labelling and therefore minimise consumers' risk. The immunoanalytical detectability of potentially allergenic peanut proteins is dependent on previous heat treatment, the extraction capacity of the applied buffer and the specificity of the antibody. In this study a lateral flow device (LFD) for the detection of peanut protein was developed and the capacity of 30 different buffers to extract proteins from mildly and strongly roasted peanut samples as well as their influence on the test strip performance were investigated. Most of the tested buffers showed good extraction capacity for putative Ara h 1 from mildly roasted peanuts. Protein extraction from dark-roasted samples required denaturing additives, which were proven to be incompatible with LFD performance. High-pH buffers increased the protein yield but inhibited signal generation on the test strip. Overall, the best results were achieved using neutral phosphate buffers but equal detectability of differently altered proteins due to food processing cannot be assured yet for immunoanalytical methods.
机译:花生的意外摄入会引起过敏者的严重健康反应。需要可靠地确定食品中花生的痕量,以支持正确的标签,从而最大程度地降低消费者的风险。潜在过敏原花生蛋白的免疫分析可检测性取决于先前的热处理,所用缓冲液的提取能力和抗体的特异性。在这项研究中,开发了一种用于检测花生蛋白的侧向流动装置(LFD),并研究了30种不同缓冲液从轻度和强度烘烤的花生样品中提取蛋白质的能力以及它们对试纸条性能的影响。大多数测试缓冲液显示出从轻度烘烤的花生中对推定的Ara h 1的良好提取能力。从深色烘焙样品中提取蛋白质需要变性添加剂,事实证明该添加剂与LFD性能不兼容。高pH缓冲液可增加蛋白质产量,但会抑制试纸条上的信号产生。总体而言,使用中性磷酸盐缓冲液可获得最佳结果,但是对于免疫分析方法,尚不能保证由于食品加工而导致不同改变的蛋白质具有相同的可检测性。

著录项

  • 来源
    《Food additives & contaminants》 |2012年第1期|p.1-11|共11页
  • 作者单位

    Christian Doppler Laboratory for Rapid Test Systems for Allergenic Food Contaminants, University of Natural Resources and Life Sciences, Vienna, Austria,Department for Agrobiotechnology, Center for Analytical Chemistry, Konrad-Lorenz Str. 20, A-3430 Tulln, Austria;

    Christian Doppler Laboratory for Rapid Test Systems for Allergenic Food Contaminants, University of Natural Resources and Life Sciences, Vienna, Austria,Department for Agrobiotechnology, Center for Analytical Chemistry, Konrad-Lorenz Str. 20, A-3430 Tulln, Austria;

    Christian Doppler Laboratory for Rapid Test Systems for Allergenic Food Contaminants, University of Natural Resources and Life Sciences, Vienna, Austria,Department for Agrobiotechnology, Center for Analytical Chemistry, Konrad-Lorenz Str. 20, A-3430 Tulln, Austria;

    Christian Doppler Laboratory for Rapid Test Systems for Allergenic Food Contaminants, University of Natural Resources and Life Sciences, Vienna, Austria,Department for Agrobiotechnology, Center for Analytical Chemistry, Konrad-Lorenz Str. 20, A-3430 Tulln, Austria;

    Christian Doppler Laboratory for Rapid Test Systems for Allergenic Food Contaminants, University of Natural Resources and Life Sciences, Vienna, Austria,Department for Agrobiotechnology, Center for Analytical Chemistry, Konrad-Lorenz Str. 20, A-3430 Tulln, Austria;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    peanuts; allergens; extraction; immunoassays;

    机译:花生;过敏原萃取;免疫测定;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号