首页> 外文期刊>Engineering Structures >Optimal tuned inerter dampers for performance enhancement of vibration isolation
【24h】

Optimal tuned inerter dampers for performance enhancement of vibration isolation

机译:最佳调谐的惯性阻尼器,可增强隔振性能

获取原文
获取原文并翻译 | 示例

摘要

This paper proposes two types of base isolation systems with tuned inerter dampers (TID) composed of a spring, an inerter and a dashpot in serial or parallel to enhance the seismic isolation performance of the traditional base-isolation system. The TID isolation systems are optimally tuned using the H-2 norm criterion to achieve the best RMS vibration performance under white-noise random excitation. The TID frequency ratio and damping ratio are defined as the design parameters, whose optimal values are analytically derived for the undamped primary system and numerically verified. The results show that the optimum exists in the serial TID isolation system (inerter and dashpot in serial layout), while in the parallel TID isolation system (inerter and dashpot in parallel layout) larger TID stiffness and larger TID damping are preferred in practice to achieve better isolation performance. The isolation performance of the H-2 optimal TID systems is also compared with that of the H-infinity optimized systems obtained numerically. The results suggest that the optimal serial TID system has overall better isolation performance over the broad frequency range, which is preferable for seismic vibration isolation because seismic waves usually contain a wide range of frequency components. The parallel Tin system cannot be tuned optimally for practical structures, nevertheless, it still achieves better isolation performance at the resonant vibrations by an appropriate selection of the design parameters. The influence of the structural parameters on the tuning parameters are studied. Numerical case studies are conducted in comparison with the traditional and tuned mass damper (TMD) isolation systems for a five-story laboratory building prototype. The potential power in the TID isolations that could be converted to usable electricity in earthquakes are also examined.
机译:为了提高传统基础隔震系统的隔震性能,本文提出了两种类型的基础隔震系统,它们具有由串联的弹簧,一个惯性减震器和一个减震器组成的可调惯性阻尼器(TID)。使用H-2规范标准对TID隔离系统进行优化调整,以在白噪声随机激励下获得最佳RMS振动性能。 TID频率比和阻尼比被定义为设计参数,其最优值通过分析得出无阻尼初级系统并进行数值验证。结果表明,在串行TID隔离系统(串行布局中的惯性和减震器)中存在最佳值,而在并行TID隔离系统(并行布局中的惯性和减震器)中,在实践中,优选较大的TID刚度和较大的TID阻尼更好的隔离性能。还将H-2最佳TID系统的隔离性能与通过数值获得的H-无限优化系统的隔离性能进行了比较。结果表明,最佳的串行TID系统在较宽的频率范围内总体上具有更好的隔离性能,这对于地震振动隔离是优选的,因为地震波通常包含很宽的频率分量。并行锡系统无法针对实际结构进行最佳调整,尽管如此,通过适当选择设计参数,它仍然可以在共振振动时实现更好的隔离性能。研究了结构参数对整定参数的影响。与五层实验室建筑原型的传统和调谐质量阻尼器(TMD)隔离系统相比,进行了数值案例研究。还检查了TID隔离中可转换为地震可用电的潜在功率。

著录项

  • 来源
    《Engineering Structures》 |2019年第1期|109464.1-109464.14|共14页
  • 作者单位

    Virginia Tech Dept Mech Engn Blacksburg VA 24061 USA;

    Virginia Tech Dept Mech Engn Blacksburg VA 24061 USA|Hunan Univ Sci & Technol Hunan Prov Key Lab Struct Engn Wind Resistant & V Xiangtan Hunan Peoples R China;

    Hunan Univ Sci & Technol Hunan Prov Key Lab Struct Engn Wind Resistant & V Xiangtan Hunan Peoples R China;

    Michigan State Univ Dept Mech Engn E Lansing MI 48824 USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Tuned inerter damper; Seismic control; Base-isolation; H-2 optimization; Energy harvesting;

    机译:调谐的惰性阻尼器;地震控制;碱基隔离H-2优化;能量收集;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号