On-line monitoring of relative dielectric losses in cross-bonded cables using sheath currents

机译:使用护套电流在线监测交叉连接电缆中的相对介电损耗

获取原文
获取原文并翻译 | 示例
           

摘要

Cross-bonded three-phase single-core Cross-linked Polyethylene (XLPE) cables are widely used in power transmission and distribution systems. A great deal has been published on on-line monitoring of HV cable systems to prevent failure. Relative Dielectric Losses (DL) monitoring reveals the general condition of the cable insulation. Generally, DL measurement relies on measuring operating voltage and insulation leakage current. The main challenge to on-line monitoring of DL in Cross-bonded High voltage (CB HV) cables is the interconnectedness of metal sheath. Measured sheath currents are a combination of the leakage currents of each section and the imbalanced circulating current. Differentiating the leakage current of each interconnected section from the measured data is complex. The second challenge is that co-axial cables are used to connect cable sheaths to cable link boxes, for ease of installation and protection against moisture. As a result, any measured value contains currents from the two sheaths connecting at a joint. The third challenge is that it is hard to obtain the reference voltage synchronously and with high accuracy. Consequently, this paper investigates separation of leakage current components and analysis of DL based on leakage currents without reference voltage. A circuit model is proposed to describe the leakage current separation method for CB HV cables to allow on-line monitoring of DL, and the criterion required for assessing relative change of DL among different phases or sections of the cable for insulation deterioration are presented. Operational measurements from a cable system are analyzed and discussed. Results show that there is no significant deterioration in this monitored major section of a CB HV cable system.
机译:交联三相单芯交联聚乙烯(XLPE)电缆广泛用于输配电系统。关于高压电缆系统的在线监控,以防止故障,已经发表了大量文章。相对介电损耗(DL)监视揭示了电缆绝缘的一般状况。通常,DL测量依赖于测量工作电压和绝缘泄漏电流。在线监测交联高压(CB HV)电缆中的DL的主要挑战是金属护套的互连性。测得的护套电流是每个部分的泄漏电流和不平衡循环电流的组合。将每个互连部分的泄漏电流与测量数据区分开是很复杂的。第二个挑战是使用同轴电缆将电缆护套连接到电缆接线盒,以简化安装并防止潮气。结果,任何测量值都包含来自在一个接头处连接的两个护套的电流。第三个挑战是很难同步,高精度地获得参考电压。因此,本文研究了泄漏电流分量的分离以及基于没有参考电压的泄漏电流的DL分析。提出了一种用于描述CB HV电缆泄漏电流分离方法的电路模型,以允许对DL进行在线监测,并提出了评估电缆的不同相或截面之间的DL相对变化以评估绝缘劣化所需的标准。分析和讨论了电缆系统的运行测量。结果表明,在CB HV电缆系统的受监控主要部分中,没有显着恶化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号