Groin hernioplasty is the most performed intervention in the adults worldwide, the minimally invasive inguinal hernia repair techniques widely used by surgeons today are transabdominal preperitoneal patch plasty (TAPP) and total extraperitoneal patch plasty (TEP). We report a 62-year-old man with bowel obstruction caused by the use of self-anchoring barbed suture to close the peritoneum 3 days after TAPP. Surgeons using the barbed suture should be alert to this possibility when encountering this complication of intestinal obstruction, so as to avoid more serious consequences.
机译:腹股沟成形术是全球成人的最具表现的干预,目前外科医生广泛使用的微创腹股沟疝修补技术是CanceAbnaminal PrectertoNeal贴剂(TAPP)和全腹膜蛋白贴剂(TEP)。 我们举报了一名62岁的男子,通过使用自锚式刺绣引起的肠梗阻造成的肠梗阻,在TAPP后3天关闭腹膜。 使用刺缝合的外科医生应在遇到这种肠梗阻并发症时对这种可能性进行警告,以避免更严重的后果。