A 50-year-old man underwent laparoscopic hernia repair for a groin hernia, presenting acute abdominal pain and bowel obstruction syndrome 1 day post surgery. Diagnostic laparoscopy was performed at postoperative the day after the hernioplasty and a volvulus was found. The residual end of the barbed V-LOC adopted in the peritoneal closure was incidentally hooked to the mesentery and caused a small bowel obstruction as a volvulus. The redundant V-LOC strand was released and cut superficial to the peritoneum. A detorsion of volvulus was preformed. Neither bowel ischemia nor significant bowel injury was noted. The following day he was discharged without complication. The residual ‘free’ barbel suture in the peritoneal cavity invited adhesion formations and subsequently the Bowel obstruction.
机译:一名50岁的男子接受腹股沟疝修补术治疗腹股沟疝,术后1天出现急性腹痛和肠梗阻综合征。疝整形术后第二天进行诊断性腹腔镜检查,发现肠扭转。腹膜闭合中带倒钩的V-LOC的残留端偶然钩在肠系膜上,并导致肠梗阻作为肠扭转。多余的V-LOC链被释放并切开至腹膜表面。扭转了小肠扭转。既没有发现肠缺血也没有发现明显的肠损伤。第二天,他出院没有并发症。腹膜腔内残留的“自由” barbel缝合线引起粘连形成,并随后引起肠梗阻。