...
首页> 外文期刊>Folia medica >In Vitro Comparison of Several Methods for Initial Proximal Caries Detection
【24h】

In Vitro Comparison of Several Methods for Initial Proximal Caries Detection

机译:初始近端龋病检测的几种方法的体外比较

获取原文
           

摘要

Introduction: Initial proximal caries is both diagnostic and therapeutic challenge. The disadvantages of the conventional methods for caries detection and the development of technologies led to the creation of contemporary optical devices for early caries detection.Aim: In vitro comparison of the diagnostic accuracy of several methods for early proximal caries detection - visual-tactile, bitewing radiography and laser fluorescence device (DIAGNOdent pen).Materials and methods: Fifty-eight proximal surfaces of extracted human permanent premolars and molars were examined by two examiners using visual inspection, bitewing radiography, DIAGNOdent with proximal contact, and DIAGNOdent directly in the lesion. Results were compared with the histological gold standard. Statistical analysis with ROC curve, sensitivity, specificity and diagnostic accuracy of each detection method was performed. Analysis was conducted in 3 diagnostic thresholds - initial, developed and advanced demineralization.Results: Sensitivity of visual inspection was 16%-33%, specificity 93.3%-100%, sensitivity of bitewing radiography 54%-67%, specificity 93%-94%, sensitivity of DIAGNOdent with proximal surfaces in contact 88%-91%, specificity 79%-89%, sensitivity of DIAGNOdent directly 89%-92.5%, specificity 81.29%-93%. The highest diagnostic accuracy, increasing with the rise of the level of demineralization, was shown by DIAGNOdent directly, followed by DIAGNOdent with proximal contact, bitewing radiography, and visual inspection with the lowest accuracy.Conclusion: The use of contemporary diagnostic devices significantly increases the possibility for early detection of proximal lesions. DIAGNOdent can be used as an adjunct to and increasing the diagnostic accuracy of the conventional caries detection methods.
机译:简介:最初的近端龋齿是诊断和治疗挑战。龋齿检测方法的缺点和技术的发展导致了用于早期龋病检测的当代光学装置的创造:在近期龋齿检测的几种方法的诊断准确性的体外比较 - 视觉触觉,BITEWING射线照相和激光荧光装置(诊断笔)。材料和方法:使用目视检查,BITEWING射线照相,近端接触的诊断,直接在病变中诊断诊断,诊断,在病变中诊断58例提取人永久磨牙和臼齿的58个近端表面。将结果与组织学黄金标准进行比较。进行统计分析,进行ROC曲线,灵敏度,特异性和诊断准确性的每种检测方法。分析是在3次诊断阈值 - 初始,发育和高级脱矿质中进行的。结果:目视检查的敏感性为16%-33%,特异性为93.3%-100%,斑纹放射照相的敏感性54%-67%,特异性为93%-94 %,近端表面的诊断敏感性88%-91%,特异性79%-89%,诊断敏感性直接89%-92.5%,特异性为81.29%-93%。最高的诊断准确性,随着脱矿质水平的增加而增加,诊断直接显示,随后用近端触点,咬合射线照相诊断和具有最低精度的目视检查。结论:使用当代诊断装置显着增加早期检测近端病变的可能性。诊断可以用作辅助和增加传统龋病检测方法的诊断准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号