The amount of polysorbate 80 in pharmaceutical formulations affects the product quality and efficacy. A reliable test method is required to quantify the amount of Polysorbate 80 present in the drug product formulations. The test method for the determination of Polysorbate 80 may be used during process development and final product quality assessment. A simple, fast and efficient quantitative method, making use of HPLC-ELSD and a C18 column without sample pretreatment was developed. The developed method demonstrated specificity to polysorbate 80 with high precision as indicated by percent relative standard deviation (%RSD) of 3.0% for six determinations. The accuracy of this method for the determination of polysorbate 80 in a pharmaceutical formulation was demonstrated with an overall recovery of 94.9%.
机译:药物制剂中的聚山梨醇酯80的量影响产品质量和功效。需要一种可靠的测试方法来量化药物制剂中存在的聚山梨醇酯80的量。用于测定聚山梨醇酯80的试验方法可以在过程开发和最终产品质量评估期间使用。开发了一种简单,快速高效的定量方法,利用HPLC-ELSD和没有样品预处理的C18柱。显影方法对聚山梨醇酯80的特异性具有高精度,如六个测定的3.0%的相对标准偏差(%RSD)所示。该方法在药物制剂中测定聚山梨醇酯80的准确性,总回收率为94.9%。