首页> 外文期刊>Frontiers in Neurology >A Preliminary Study of Effects of Channel Number and Location on the Repeatability of Motor Unit Number Index (MUNIX)
【24h】

A Preliminary Study of Effects of Channel Number and Location on the Repeatability of Motor Unit Number Index (MUNIX)

机译:频道数量与位置对电机单位数指数重复性的初步研究(MUNIX)

获取原文
       

摘要

Motor Unit Number Index (MUNIX) is a technique that provides a susceptive biomarker for monitoring innervation conditions in patients with neurodegenerative diseases. A satisfactory repeatability is essential for the interpretation of MUNIX results. This study aims to examine the effect of channel number and location on the repeatability of MUNIX. In this study, 128 channels of high-density surface electromyography (EMG) signals were recorded from the biceps brachii muscles of eight healthy participants, at 10, 20, 30, 40, 50, 60, 70, 80, and 100% of maximal voluntary contraction. The repeatability was defined by the coefficient of variation (CV) of MUNIX estimated from three experiment trials. Single-channel MUNIX (sMUNIX) was calculated on a channel-specific basis and a multi-channel MUNIX (mMUNIX) approach as the weighted average of multiple sMUNIX results. Results have shown (1) significantly improved repeatability with the proposed mMUNIX approach; (2) a higher variability of sMUNIX when the recording channel is positioned away from the innervation zone. Our results have demonstrated that (1) increasing the number of EMG channels and (2) placing recording channels close to the innervation zone (IZ) are effective methods to improve the repeatability of MUNIX. This study investigated two potential causes of MUNIX variations and provided novel perspectives to improve the repeatability, using high-density surface EMG. The mMUNIX technique proposed can serve as a promising tool for reliable neurodegeneration evaluation.
机译:电机单位编号指数(MUNIX)是一种提供易受敏感生物标志物的技术,用于监测神经变性疾病患者的支配条件。令人满意的可重复性对于Mulix结果的解释至关重要。本研究旨在研究渠道数量和位置对munix重复性的影响。在本研究中,从八个健康参与者的二头肌Brachii肌肉记录了128个高密度表面肌电图(EMG)信号,10,20,30,40,50,60,70,80和100%的最大值自愿收缩。通过三个实验试验估计的Munix的变异系数(CV)定义了可重复性。单通道MUNIX(SMUNIX)由特定于频道特定的基础计算,多声道MUNIX(MMUNIX)方法是多个SMUNIX结果的加权平均值。结果显示(1)与提出的Mmunix方法显着提高了重复性; (2)当记录通道远离支撑区域时,Smunix的更高可变性。我们的结果表明,(1)增加了EMG通道的数量和(2)将靠近金属化区的记录通道(IZ)的销售通道是有效的改善MUNIX重复性的有效方法。本研究调查了MUNIX变化的两个潜在原因,并提供了使用高密度表面EMG改善重复性的新颖的视角。所提出的MMUNIX技术可以作为可靠的神经变性评估的有希望的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号