Rapid anaerobe identification (MicroScan) panels (4 h) were evaluated both visually and by the AutoScan-4, a computer-controlled microplate reader. The results of both reading methods were compared with identifications obtained by the conventional (Virginia Polytechnic Institute) method. In total, 237 anaerobes were tested. Correct identifications were obtained for 166 strains (70%) by visual reading and 157 strains (66.2%) by the AutoScan-4. Supplementary tests resulted in 80.1 and 76.7% total correct identifications, respectively. Comparison of the two reading methods revealed complete agreement for 169 strains. Differences between the two reading methods were due to difficulties in reading specific reactions. This was especially true with the clostridial species. The performance of the MicroScan system in the identification of anaerobic bacteria appears comparable to that of other 4-h identification systems for anaerobes, but this system shows significant variance from the conventional system. Improvements in the trays and data base are required before the system can be recommended for routine use.
机译:快速厌氧菌鉴定(MicroScan)面板(4 h)在视觉上和通过AutoScan-4(计算机控制的酶标仪)进行评估。将两种读取方法的结果与通过常规方法(弗吉尼亚理工学院)获得的鉴定结果进行比较。总共测试了237种厌氧菌。通过视觉读取获得了166个菌株(70%)的正确鉴定,通过AutoScan-4获得了157个菌株(66.2%)的正确鉴定。补充测试分别得出正确识别的总数为80.1和76.7%。两种读取方法的比较表明,对于169个菌株完全一致。两种阅读方法之间的差异是由于难以阅读特定的反应。对于梭菌物种尤其如此。 MicroScan系统在厌氧细菌识别中的性能似乎可与其他4小时厌氧菌识别系统的性能相媲美,但该系统与常规系统相比有很大差异。在建议将该系统例行使用之前,需要对纸盘和数据库进行改进。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号