A total of 525 stool specimens collected during 1 year were examined for the presence of rotavirus by direct electron microscopy (EM), enzyme-linked immunosorbent assay (ELISA), and a solid-phase immune electron microscope method (SPIEM) utilizing protein A-coated grids for anchoring of specific viral antisera. Rotavirus was seen in 187 specimens; SPIEM detected 183 (97.8%), whereas direct EM and ELISA detected 161 (86%) and 166 (88.7%), respectively. No false-positive reactions were seen by ELISA. The sensitivity of the methods was evaluated by coded investigation of a dilution series of a positive sample, with a negative fecal specimen as diluent. SPIEM was approximately 30 times more sensitive than direct EM and 10 times more sensitive than ELISA. A study was done to compare the elapsed time for recognition of rotavirus by SPIEM and EM in 25 randomly selected positive specimens. All virus-positive specimens were detected within 2 min by SPIEM, whereas up to 9 min was required for direct EM. SPIEM with protein A is a highly sensitive method, useful for rapid detection of viruses in clinical specimens. Due to the direct visualization of virus particles by electron microscopy, there is no requirement for monospecific antisera for the method.
机译:通过直接电子显微镜(EM),酶联免疫吸附测定(ELISA)和利用蛋白A-的固相免疫电子显微镜方法(SPIEM)检查了1年期间收集的总共525个粪便标本中是否存在轮状病毒。带涂层的网格用于锚定特定的病毒抗血清。在187个标本中发现了轮状病毒。 SPIEM检测到183(97.8%),而直接EM和ELISA检测到161(86%)和166(88.7%)。 ELISA未见假阳性反应。通过对阳性样品的稀释系列进行编码研究(以阴性粪便样品作为稀释剂)来评估方法的敏感性。 SPIEM的灵敏度比直接EM高30倍,比ELISA高10倍。进行了一项研究,以比较SPIEM和EM在25个随机选择的阳性标本中识别轮状病毒所花费的时间。 SPIEM在2分钟内检测到所有病毒阳性标本,而直接EM则需要9分钟。带有蛋白质A的SPIEM是高度敏感的方法,可用于快速检测临床标本中的病毒。由于可以通过电子显微镜直接观察病毒颗粒,因此该方法不需要单特异性抗血清。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号