首页> 外文期刊>IFAC PapersOnLine >Method Comparison and Validation of the Determination of Ejection Duration from Oscillometric Measurements
【24h】

Method Comparison and Validation of the Determination of Ejection Duration from Oscillometric Measurements

机译:示波法测定射血持续时间的方法比较和验证

获取原文
   

获取外文期刊封面封底 >>

       

摘要

The ejection duration (ED) is an important indicator of ventricular function as well as ventriculo-arterial coupling, especially for heart failure with reduced ejection fraction. Thus, the non-invasive oscillometric determination of ED from arterial pressure waves could enhance methods of pulse wave analysis. The aim of this work was to compare different approaches to calculate the ED from oscillometric measurements and to test and to validate the determination of ED with results from measurements using radial tonometry. Oscillometric and tonometric pulse wave measurements were obtained in direct succession from each patient with the Mobil-O-Graph and with the Sphygmocor device in a comparative study. Also, the results from the internal algorithm of SphygmoCor were obtained. Several methods for the determination of ED were implemented and applied to the given measurements. The results of Mobil-O-Graph were compared with the ejection durations from the internal algorithm of SphygmoCor. Several algorithms had a mean error lower than the step size of the recordings. The algorithm using numerical central differences to find the maximum curvature of the curve was chosen for the determination of ED due to its lowest standard deviation compared with others, its low mean error and its stability. The mean difference between Mobil-O-Graph and SphygmoCor was 7 ms (35 SD). An algorithm for determination of ED was selected and tested successfully on radial and brachial recordings. As the differences between locations as well as between algorithms are sufficiently small, the determination of ejection duration from brachial oscillometric pulse waves seems feasible.
机译:射血持续时间(ED)是心室功能以及心室-动脉耦合的重要指标,尤其是对于心力衰竭而射血分数降低的患者。因此,用动脉压波无创示波法测定ED可以增强脉搏波分析的方法。这项工作的目的是比较使用示波测量法计算ED的不同方法,以及使用径向眼压测量法测量结果来测试和验证ED的确定。在比较研究中,通过Mobil-O-Graph和Sphygmocor装置从每位患者中直接连续获得了示波法和眼压计脉搏波测量值。此外,还从SphygmoCor的内部算法获得了结果。实施了几种测定ED的方法,并将其应用于给定的测量。将Mobil-O-Graph的结果与SphygmoCor内部算法的喷射持续时间进行比较。几种算法的平均误差低于记录的步长。选择ED的方法是使用数值中心差来找到曲线的最大曲率,因为ED与其他方法相比具有最低的标准偏差,较低的平均误差和稳定性。 Mobil-O-Graph和SphygmoCor之间的平均差为7 ms(35 SD)。选择了一种确定ED的算法,并在radial骨和肱骨记录中成功进行了测试。由于位置之间以及算法之间的差异足够小,因此从肱骨示波脉冲波确定喷射持续时间似乎是可行的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号