Objectives The purpose of this study was to determine intraobserver, interobserver, and inter‐day reliability levels for stiffness measurements of the patellar tendon and rectus femoris muscle using shear wave elastography (SWE). Methods This study was conducted on 12 healthy male individuals. Two examiners measured mean shear wave velocity values of the patellar tendons and rectus femoris muscles of both extremities using a 9L4 (4‐9 MHz) transducer and an Acuson S3000 ultrasound system (Siemens Medical Solutions, Mountain View, CA). The elasticity images were acquired by the Virtual Touch tissue imaging quantification technique (Siemens Medical Solutions). Measurements were repeated 20 minutes and 1 week after the first measurements. The reliability of SWE measurements was assessed by means of the intraclass correlation coefficient (ICC). Results The 12 participants ranged in age from 19 to 33 years (mean age?±?SD, 25.33?±?4.56 years). For the patellar tendon stiffness measurements with SWE, it was found that intraobserver reliability (ICC, 0.91–0.92) and interday reliability (ICC, 0.81–0.83) were excellent, and interobserver reliability (ICC, 0.71) was good. For the rectus femoris muscle stiffness measurements with SWE, it was found that the intraobserver reliability (ICC, 0.93–0.94), interday reliability (ICC, 0.81–0.91), and interobserver reliability (ICC, 0.95) were perfect. Conclusions Shear wave elastography using the Virtual Touch tissue imaging quantification technique is a reliable and repeatable technique for patellar tendon and rectus femoris stiffness measurements according to intraobserver, interday, and interobserver ICC values.
机译:目的本研究的目的是确定使用剪切波弹性成像(SWE)测量measurements骨肌腱和股直肌的刚度的观察者内,观察者间和日间可靠性水平。方法本研究针对12名健康男性。两名检查员使用9L4(4-9 MHz)换能器和Acuson S3000超声系统(Siemens Medical Solutions,Mountain View,CA)测量了两肢the骨肌腱和股直肌的平均剪切波速度值。弹性图像通过虚拟触摸组织成像定量技术(Siemens Medical Solutions)获得。首次测量后20分钟和1周重复测量。 SWE测量的可靠性通过类内相关系数(ICC)进行评估。结果12名参与者的年龄从19岁到33岁不等(平均年龄为±SD,25.33±4.56岁)。对于使用SWE进行的tell肌腱刚度测量,发现观察者内可靠性(ICC,0.91-0.92)和日间可靠性(ICC,0.81-0.83)极好,观察者间可靠性(ICC,0.71)很好。对于使用SWE进行的股直肌肌肉刚度测量,发现观察者内可靠性(ICC,0.93-0.94),日间可靠性(ICC,0.81-0.91)和观察者间可靠性(ICC,0.95)是完美的。结论使用虚拟触摸组织成像定量技术的剪切波弹性成像技术是根据观察者内,观察者间和观察者间ICC值测量pa骨肌腱和股直肌僵硬度的可靠且可重复的技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号