A sensitive and selective method has been proposed for the simultaneous determination of amlodipine (AML), valsartan (VAL) and hydrochlorothiazide (HCTZ) in human plasma by liquid chromatography–tandem mass spectrometry (LC–MS/MS). The analytes and their deuterated analogs were quantitatively extracted from 100μL human plasma by solid phase extraction on Oasis HLB cartridges. The chromatographic separation of the analytes was achieved on a Chromolith RP 18e (100mm × 4.6mm) analytical column within 2.5min. The resolution factor between AML and VAL, AML and HCTZ, and VAL and HCTZ was 2.9, 1.5 and 1.4, respectively, under isocratic conditions. The method was validated over a dynamic concentration range of 0.02–20.0ng/mL for AML, 5.00–10,000ng/mL for VAL and 0.20–200ng/mL for HCTZ. Ion-suppression/enhancement effects were investigated by post-column infusion technique. The mean IS-normalized matrix factors for AML, VAL and HCTZ were 0.992, 0.994 and 0.998, respectively. The intra-batch and inter-batch precision (% CV) across quality control levels was ≤ 5.56% and the recovery was in the range of 93.4%–99.6% for all the analytes. The method was successfully applied to a bioequivalence study of 5mg AML + 160mg VAL + 12.5mg HCTZ tablet formulation (test and reference) in 18 healthy Indian males under fasting. The mean log-transformed ratios of C max , AUC 0–120h and AUC 0-inf and their 90% CIs were within 90.2%–102.1%. The assay reproducibility was demonstrated by reanalysis of 90 incurred samples.
机译:液相色谱-串联质谱法(LC-MS / MS)提出了一种灵敏且选择性的方法同时测定人血浆中的氨氯地平(AML),缬沙坦(VAL)和氢氯噻嗪(HCTZ)。在Oasis HLB柱上通过固相萃取从100μL人血浆中定量萃取分析物及其氘代类似物。在2.5分钟内在Chromolith RP 18e(100mm×4.6mm)分析柱上完成分析物的色谱分离。在等度条件下,AML和VAL,AML和HCTZ以及VAL和HCTZ之间的分辨率因子分别为2.9、1.5和1.4。该方法在AML动态浓度范围为0.02–20.0ng / mL,VAL在5.00–10,000ng / mL和HCTZ为0.20–200ng / mL的动态浓度范围内得到验证。通过柱后注入技术研究了离子抑制/增强作用。 AML,VAL和HCTZ的平均IS标准化矩阵因子分别为0.992、0.994和0.998。跨质量控制水平的批内和批间精度(%CV)≤5.56%,所有分析物的回收率均在93.4%–99.6%之间。该方法已成功应用于禁食下18例健康的印度男性中5mg AML + 160mg VAL + 12.5mg HCTZ片剂的生物等效性研究(测试和参考)。 C max,AUC 0–120h和AUC 0-inf及其90%CI的平均对数转换比率在90.2%–102.1%之内。通过对90个发生的样品进行重新分析证明了测定的可重复性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号