...
首页> 外文期刊>Journal of Foot and Ankle Research >The reliability of non-invasive biophysical outcome measures for evaluating normal and hyperkeratotic foot skin
【24h】

The reliability of non-invasive biophysical outcome measures for evaluating normal and hyperkeratotic foot skin

机译:用于评估正常和过度角化的足部皮肤的非侵入性生物物理结果指标的可靠性

获取原文
           

摘要

Background Hyperkeratosis of foot skin is a common skin problem affecting people of different ages. The clinical presentation of this condition can range from dry flaky skin, which can lead to fissures, to hard callused skin which is often painful and debilitating. The purpose of this study was to test the reliability of certain non-invasive skin measurement devices on foot skin in normal and hyperkeratotic states, with a view to confirming their use as quantitative outcome measures in future clinical trials. Methods Twelve healthy adult participants with a range of foot skin conditions (xerotic skin, heel fissures and plantar calluses) were recruited to the study. Measurements of normal and hyperkeratotic skin sites were taken using the following devices: Corneometer? CM 825, Cutometer? 580 MPA, Reviscometer? RVM 600, Visioline? VL 650 Quantiride? and Visioscan? VC 98, by two investigators on two consecutive days. The intra and inter rater reliability and standard error of measurement for each device was calculated. Results The data revealed the majority of the devices to be reliable measurement tools for normal and hyperkeratotic foot skin (ICC values?>?0.6). The surface evaluation parameters for skin: SEsc and SEsm have greater reliability compared to the SEr measure. The Cutometer? is sensitive to soft tissue movement within the probe, therefore measurement of plantar soft tissue areas should be approached with caution. Reviscometer? measures on callused skin demonstrated an unusually high degree of error. Conclusions These results confirm the intra and inter rater reliability of the Corneometer?, Cutometer?, Visioline? and Visioscan? in quantifying specific foot skin biophysical properties.
机译:背景技术足部皮肤过度角化是影响不同年龄人群的常见皮肤问题。这种状况的临床表现可能从干燥的片状皮肤(可能导致裂痕)到硬call的皮肤(通常会造成疼痛和虚弱)。这项研究的目的是测试正常和过度角化状态下某些非侵入性皮肤测量设备在足部皮肤上的可靠性,以确认其在将来的临床试验中作为定量结果测量的用途。方法招募十二名健康成人,参与者具有多种足部皮肤状况(干燥性皮肤,足跟裂痕和足底老茧)。使用以下设备进行了正常和角化过度的皮肤部位的测量:角膜仪? CM 825,Cutometer? 580 MPA,粘度计? RVM 600,Visioline? VL 650 Quantiride?和Visioscan? VC 98,由两名调查员在连续两天内进行。计算每个设备的内部和内部评估者可靠性以及测量的标准误差。结果数据表明,大多数设备是正常和角化过度的脚皮肤的可靠测量工具(ICC值≥0.6)。皮肤的表面评估参数:SEsc和SEsm与SEr度量相比具有更高的可靠性。切割表?探头对软组织的运动敏感,因此应谨慎进行足底软组织区域的测量。粘度计?对老茧皮肤的措施显示出异常高的错误率。结论这些结果证实了Corneometer?,Cutometer?,Visioline?的内部和内部评估者可靠性。和Visioscan?定量特定的脚部皮肤生物物理特性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号