Statement of Problem: Various impression techniques have different effects on the accuracy of final cast dimensions. Meanwhile; there are some controversies about the best technique. Purpose: This study was performed to compare two kinds of implant impression methods (open tray and closed tray) on 15 degree angled implants. Materials and Method: In this experimental study, a steel model with 8 cm in diameter and 3 cm in height were produced with 3 holes devised inside ?to stabilize 3 implants. The central implant was straight and the other two implants were 15° angled. The two angled implants had 5 cm distance from each other and 3.5 cm from the central implant. Dental stone, high strength (type IV) was used for the main casts. Impression trays were filled with poly ether, and then the two impression techniques (open tray and closed tray) were compared. To evaluate positions of the implants, each cast was analyzed by CMM device in 3 dimensions (x,y,z). Differences in the measurements obtained from final casts and laboratory model were analyzed using t-Test. Results: The obtained results indicated that closed tray impression technique was significantly different in dimensional accuracy when compared with open tray method. Dimensional changes were 129 ± 37μ and 143.5 ± 43.67μ in closed tray and open tray, while coefficient of variation in closed- tray and open tray were reported to be 27.2% and 30.4%, respectively. Conclusion: Closed impression technique had less dimensional changes in comparison with open tray method, so this study suggests that closed tray impression technique is more accurate.
机译:问题陈述:各种压印技术对最终铸件尺寸的精度有不同的影响。与此同时;关于最佳技术存在一些争议。目的:进行这项研究以比较15度成角度植入物上的两种植入物压印方法(开放式托盘和封闭式托盘)。材料和方法:在本实验研究中,制作了直径8厘米,高3厘米的钢模型,并在其内部设计了3个孔以稳定3个植入物。中心植入物是笔直的,其他两个植入物成15°角。两个成角度的植入物彼此之间有5 cm的距离,与中央植入物有3.5 cm的距离。主铸件使用了高强度的牙石(IV型)。压印托盘中装有聚醚,然后比较了两种压印技术(开放式托盘和封闭式托盘)。为了评估植入物的位置,每个铸件都由CMM设备在3个维度(x,y,z)中进行了分析。使用t检验分析从最终铸件和实验室模型获得的测量值差异。结果:获得的结果表明,与开放式托盘法相比,封闭式托盘压印技术在尺寸精度上有显着差异。封闭托盘和开放托盘的尺寸变化为129±37μ和143.5±43.67μ,而封闭托盘和开放托盘的变化系数据报道分别为27.2%和30.4%。结论:封闭式印模技术与开放式托盘法相比尺寸变化较小,因此本研究表明封闭式印模技术更为准确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号