BackgroundMyocardial arterial spin labeling (ASL) is a noninvasive MRI based technique that is capable of measuring myocardial blood flow (MBF) in humans. It suffers from poor sensitivity to MBF due to high physiological noise (PN). This study aims to determine if the sensitivity of myocardial ASL to MBF can be improved by reducing image acquisition time, via parallel imaging.MethodsMyocardial ASL scans were performed in 7 healthy subjects at rest using flow-sensitive alternating inversion recovery (FAIR) tagging and balanced steady state free precession (SSFP) imaging. Sensitivity encoding (SENSE) with a reduction factor of 2 was used to shorten each image acquisition from roughly 300?ms per heartbeat to roughly 150?ms per heartbeat. A paired Student’s t-test was performed to compare measurements of myocardial blood flow (MBF) and physiological noise (PN) from the reference and accelerated methods.ResultsThe measured PN (mean?±?standard deviation) was 0.20?±?0.08?ml/g/min for the reference method and 0.08?±?0.05?ml/g/min for the accelerated method, corresponding to a 60% reduction. PN measured from the accelerated method was found to be significantly lower than that of the reference method (p?=?0.0059). There was no significant difference between MBF measured from the accelerated and reference ASL methods (p?=?0.7297).ConclusionsIn this study, significant PN reduction was achieved by shortening the acquisition window using parallel imaging with no significant impact on the measured MBF. This indicates an improvement in sensitivity to MBF and may also enable the imaging of subjects with higher heart rates and imaging during systole.
机译:背景技术心肌动脉自旋标记(ASL)是一种基于MRI的非侵入性技术,能够测量人的心肌血流量(MBF)。由于高生理噪声(PN),它对MBF的敏感性较差。这项研究旨在确定是否可以通过减少平行图像的采集时间来改善心肌ASL对MBF的敏感性。方法:对7名健康受试者在静息状态下进行血流敏感交替反转恢复(FAIR)标记和平衡,以进行心肌ASL扫描稳态自由进动(SSFP)成像。减少因子为2的灵敏度编码(SENSE)用于将每个图像采集时间从每个心跳大约300微秒缩短到每个心跳大约150微秒。进行配对学生t检验,比较参考方法和加速方法测得的心肌血流量(MBF)和生理噪声(PN)。结果测得的PN(平均值±标准偏差)为0.20±±0.08?ml参考方法为/ g / min,加速方法为0.08±0.05 0.05ml / g / min,相当于减少了60%。发现用加速法测得的PN明显低于参考法的PN(p = 0.0059)。加速和参考ASL方法测得的MBF之间没有显着差异(p?=?0.7297)。结论在这项研究中,通过使用平行成像缩短采集窗口缩短了PN值,而对测量的MBF却没有显着影响。这表明对MBF的敏感性有所提高,并且还可能使具有较高心率的受试者成像并在心脏收缩期间成像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号