首页> 外文期刊>Journal of Biomedical Science and Engineering >Imaging characteristics of metallic interbody spacers: in vitro score evaluation of susceptibility artifacts considering different MRI sequences
【24h】

Imaging characteristics of metallic interbody spacers: in vitro score evaluation of susceptibility artifacts considering different MRI sequences

机译:金属椎间间隔物的成像特性:考虑不同MRI序列的敏感性伪像的体外评分评估

获取原文
           

摘要

Aim: Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium, carbon or cobalt-chrome, which can affect the post- fusion MRI scans. Implant-related susceptibility artifacts can decrease the quality of MRI scans, thwar- ting proper evaluation. This cadaver study aimed to demonstrate the extent that implant-related MRI artifacting affects the post-fusion evaluation of intervertebral spacers. Methods: In a cadaveric porcine spine, we evaluated the post-implantation MRI scans of 2 metallic intervertebral spacers (TiAL6V4, CoCrMo) that differed in shape, material, surface qualities and implantation technique. A spacer made of human cortical bone was used as a control. The median sagittal MRI slice was divided into 12 regions of interest (ROI). Results: No significant differences were found on 15 different MRI sequences read independently by an interobserver-validated team of specialists (P>0.05). Artifact-affected image quality was rated on a score of 0-1-2. A maximum score of 24 points (100%) was possible. Turbo spin echo sequences produced the best scores for all spacers and the control. Only the control achieved a score of 100%. The titanium and cobalt-chrome spacers scored 62.5% and 50%, respectively. Conclusions: Our scoring system allowed us to create an implant-related rank- ing of MRI scan quality in reference to the control that was independent of artifact dimensions. Even with turbo spin echo sequences, the susceptibility artifacts produced by the metallic spacers showed a high degree of variability. Despite optimum sequen- cing, implant design and material are relevant factors in MRI artifacting.
机译:目的:用于前路脊柱融合的椎间间隔物由不同的材料制成,例如钛,碳或钴铬合金,它们会影响融合后的MRI扫描。植入物相关的敏感性伪像会降低MRI扫描的质量,从而影响正确的评估。这项尸体研究旨在证明与植入物相关的MRI伪影会影响椎间间隔物融合后评估的程度。方法:在尸体猪脊柱中,我们评估了2种金属椎间间隔物(TiAL6V4,CoCrMo)在形状,材料,表面质量和植入技术上均不同的植入后MRI扫描。由人皮质骨制成的间隔物用作对照。将中位矢状MRI切片分为12个感兴趣区域(ROI)。结果:经观察员确认的专家组独立读取的15个不同MRI序列没有发现显着差异(P> 0.05)。受伪影影响的图像质量的评分为0-1-2。最高分数为24分(100%)。 Turbo自旋回波序列为所有间隔物和对照产生了最高分。只有对照达到100%的分数。钛和钴铬垫片的得分分别为62.5%和50%。结论:我们的评分系统使我们能够建立与植入物相关的MRI扫描质量等级,并参考与假体尺寸无关的对照。即使具有涡轮自旋回波序列,由金属间隔物产生的磁化伪影也显示出高度的可变性。尽管排序最佳,但植入物的设计和材料仍是MRI伪影的相关因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号