首页> 外文期刊>Open Journal of Medical Imaging >Score Evaluation of MRI Sequence Type Related Artifacts after Interbody Fusion with Metallic Implants—A Spine Specimen Study
【24h】

Score Evaluation of MRI Sequence Type Related Artifacts after Interbody Fusion with Metallic Implants—A Spine Specimen Study

机译:金属植入物椎间融合后MRI序列类型相关伪像的评分评估—脊柱标本研究

获取原文
           

摘要

Introduction: According to anterior spine fusion intervertebral disc spacers made of titanium or cobalt-chromium al-loys are of special interest. With regard to postoperative problems implant related artifacts can lead to a decreased MRI evaluation. The focus of this study was to compare the respective implant artifact artifact range dependend on different MRI sequences. To simplify artifact evaluation we introduced in this study a new developed 0-1-2 score. Material and Methods: We performed an MRI artifact evaluation of 2 different metallic intervertebral disc spacers (cobalt-chromium and titanium alloy). A carcass porcine spine was employed. Considering 12 defined spinal regions of interest we evaluated the respective implant artifact properties independent from the total artifact volume by using a new developed 0-1-2 score. The artifact range was documented for 15 different MRI-sequences. Results: For the titanium spacer as well as the cobalt-chromium-spacer an MRI evaluation of the implant/disc space situation could not be carried out. In contrast to the cobalt chromium spacer the titanium spacer allowed a good differentiation of the spinal canal opposite to the implant. Optimal MRI imaging results for both metallic intervertebral disc spacers could be achieved considering TSE sequences. Conclusion: A comparison of these two metallic spacers showed in all examined sequences clear advantages in favour of the titanium spacer. The best MRI representation of both tested implants by reducing implant related artifacts could be achieved with fast spin echo (TSE-) sequences. In spite of the use of TSE sequences a variability of susceptibility artifacts has to be included with regard to implant shape and material. With regard to the results of this study the easy use of a new developed artifact score represented a useful help to compare implant related MRI artifact properties independent from the actual implant related total artifact volume.
机译:简介:根据前路脊柱融合术,由钛或钴铬合金制成的椎间盘垫片特别受关注。关于术后问题,植入物相关的伪影可能会导致MRI评估降低。这项研究的重点是比较依赖于不同MRI序列的各个植入物伪影范围。为了简化工件评估,我们在本研究中引入了新开发的0-1-2分数。材料和方法:我们对2种不同的金属椎间盘垫片(钴铬合金和钛合金)进行了MRI伪影评估。使用体猪脊柱。考虑到12个感兴趣的定义脊椎区域,我们通过使用新开发的0-1-2评分独立于总假体体积评估了各自的植入物假体属性。记录了15种不同MRI序列的伪影范围。结果:对于钛垫片和钴铬垫片,无法对植入物/椎间盘的空间情况进行MRI评价。与钴铬隔离物相反,钛隔离物允许与植入物相对的椎管的良好分化。考虑到TSE序列,可以获得两种金属椎间盘垫片的最佳MRI成像结果。结论:在所有检查的顺序中对这两种金属垫片的比较显示出明显的优势,有利于钛垫片。使用快速自旋回波(TSE-)序列可通过减少与植入物有关的伪影来实现两种测试植入物的最佳MRI表现。尽管使用了TSE序列,但仍必须包括关于植入物形状和材料的敏感性伪影的可变性。关于这项研究的结果,易于使用的新开发的人工产物评分代表了一个有用的帮助,可以比较与种植体相关的MRI人工产物特性,而与实际的与种植体相关的总人工产物总量无关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号