首页> 外文期刊>Journal of Analytical & Bioanalytical Techniques >High Throughput LC-MS/MS Method for Simultaneous Estimation of 9-Cis-Retinoic Acid and its Metabolite 4-Oxo-9-Cis-Retinoic Acid in Human Plasmaand its Application to a Bioequivalence Study
【24h】

High Throughput LC-MS/MS Method for Simultaneous Estimation of 9-Cis-Retinoic Acid and its Metabolite 4-Oxo-9-Cis-Retinoic Acid in Human Plasmaand its Application to a Bioequivalence Study

机译:高通量LC-MS / MS方法同时估算人血浆中的9-Cis-视黄酸及其代谢产物4-Oxo-9-Cis-视黄酸及其在生物等效性研究中的应用

获取原文
       

摘要

A liquid chromatography mass-spectrometric method is described for the simultaneous estimation of 9-cisretinoic acid and 4-oxo-9-cis-retinoic acid in human plasma using 13-cis-retinoic acid-d5 as an internal standard. Chromatographic separation of these retinoids was achieved on Chromolith Performance RP18 (100 × 4.6 mm) column using binary flow program of two mobile phase. 9-cis-retinoic acid and 4-oxo-9-cis-retinoic acid were extracted from human plasma by liquid-liquid extraction with a mixture of ethyl acetate, n-hexane and iso propyl alcohol (30:65:5, v/v/v). Quantification was achieved by monitoring transitions of m/z 299.4→255.2 for 9-cisretinoic acid, m/z 313.4→269.3 for 4-oxo-9-cis-retinoic acid and 304.4→260.2 for isotretinoin-d5 in multiple reaction monitoring, using turbo ion source in negative polarity. The linearity was established over a dynamic range of 2.85- 450.51 ng/mL and 2.33-180.57 ng/mL for 9-cis-retinoic acid and 4-oxo-9-cis-retinoic acid, respectively. At the lower limit of quantification level, the intra-and inter-day precision values of 9-cis-retinoic acid were within 5.9% and 6.0%, respectively, whereas that of 4-oxo-9-cis-retinoic acid were within 13.8% and 11.3%, respectively. The method was successfully applied for the simultaneous estimation of 9-cis-retinoic acid and 4-oxo-9-cis-retinoic acid in healthy volunteers, after oral administration of 30 mg alitretinoin capsule for bioequivalence study.
机译:描述了一种液相色谱质谱法,使用13-顺-视黄酸-d5作为内标,同时估算人血浆中的9-顺-视黄酸和4-氧代-9-顺-视黄酸。使用两个流动相的二元流程序,在Chromolith Performance RP18(100×4.6 mm)色谱柱上实现了这些类维生素A的色谱分离。用乙酸乙酯,正己烷和异丙醇(30:65:5,v / v)的液-液萃取法从人血浆中提取9-顺-视黄酸和4-氧-9-顺-视黄酸v / v)。通过在多反应监测中监测m / z 29-→视黄醛酸的m / z 299.4→255.2、4-oxo-9-顺-视黄酸的m / z 313.4→269.3和异维甲酸-d5的304.4→260.2的转变来实现定量涡轮离子源负极性。在9-顺式-视黄酸和4-氧代-9-顺式-视黄酸的动态范围分别为2.85-450.51ng / mL和2.33-180.57ng / mL的范围内建立线性。在定量下限下,9-顺式-视黄酸的日内和日间精度值分别在5.9%和6.0%之内,而4-氧代-9-顺式-视黄酸的日内精度值在13.8之内%和11.3%。口服30 mg阿维A酸胶囊进行生物等效性研究后,该方法成功地用于健康志愿者的9-顺-视黄酸和4-氧代9-顺-视黄酸的同时测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号