首页> 外文期刊>Journal of Anaesthesiology Clinical Pharmacology >Comparison of polyvinyl chloride, curved reinforced, and straight reinforced endotracheal tubes for tracheal intubation through Airtraq? laryngoscope in anesthetized patients
【24h】

Comparison of polyvinyl chloride, curved reinforced, and straight reinforced endotracheal tubes for tracheal intubation through Airtraq? laryngoscope in anesthetized patients

机译:通过Airtraq?进行气管插管的聚氯乙烯,弯曲增强型和直形增强气管插管的比较麻醉患者的喉镜

获取原文

摘要

Background and Aims: The Airtraq? video laryngoscope facilitates tracheal intubations in patients with difficult airway or cervical spine immobilization. However, curved reinforced tracheal tube and straight reinforced tracheal tubes are useful where neck of the patient is likely to be moved or flexed or if patient is in prone position, wherein nonreinforced endotracheal tube (ETT) might get kinked and/or compressed. We compared intubation success rate of curved and straight reinforced tracheal tubes with polyvinyl chloride (PVC) tracheal tube using Airtaq? laryngoscope in paralyzed and anesthetized patients. Material and Methods: Totally, 120 patients underwent random allocation to one of the three groups using computer-generated randomization table. Patients were intubated with appropriate size and type of ETT using Airtraq? after obtaining optimal glottis view. Experienced anesthesiologist performed endotracheal intubation and unblinded observer noted down success and ease of intubation. Results: Patients intubated with PVC tube (100%) had higher rates of successful intubation and shorter intubation time (4 s), in comparison to intubation with curved reinforced (92.5%) and straight reinforced tubes (SRTs) (85%) using Airtraq? laryngoscope (AL). However, there was no statistical difference in the incidence of airway trauma among all the three groups. Conclusions: PVC tracheal tube is significantly superior to both curved and SRTs for intubation using AL.
机译:背景和目的:Airtraq?电子喉镜可帮助气道困难或颈椎固定的患者进行气管插管。但是,弯曲的气管导管和笔直的气管导管在患者的颈部可能会移动或弯曲或患者处于俯卧的位置时很有用,在这种情况下,未增强的气管导管(ETT)可能会扭结和/或受压。我们使用Airtaq®将弯曲的和直的加强型气管导管与聚氯乙烯(PVC)气管导管的插管成功率进行了比较。瘫痪和麻醉患者的喉镜。材料和方法:总共使用计算机生成的随机表将120例患者随机分配到三组之一。使用Airtraq?向患者插管合适大小和类型的ETT。获得最佳声门视图后。经验丰富的麻醉师进行了气管插管,无盲观察者指出成功率和插管的难易程度。结果:与使用Airtraq的弯曲增强管(92.5%)和笔直增强管(SRTs)进行插管(85%)相比,用PVC管进行插管(100%)的患者具有较高的成功插管率和较短的插管时间(4 s)。 ?喉镜(AL)。但是,三组之间的气道创伤发生率均无统计学差异。结论:对于使用AL进行插管,PVC气管导管显着优于弯曲导管和SRT导管。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号