首页> 外文期刊>Journal of Analytical Methods in Chemistry >Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva
【24h】

Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva

机译:LC-MS / MS方法的开发和验证,以及与GC-MS方法进行比较以测量人脑透析液,血液和唾液中的苯妥英钠

获取原文
           

摘要

Phenytoin (PHT) is one of the most often used critical dose drugs, where insufficient or excessive dosing can have severe consequences such as seizures or toxicity. Thus, the monitoring and precise measuring of PHT concentrations in patients is crucial. This study develops and validates an LC-MS/MS method for the measurement of phenytoin concentrations in different body compartments (i.e., human brain dialysate, blood, and saliva) and compares it with a formerly developed GC-MS method that measures PHT in the same biological matrices. The two methods are evaluated and compared based on their analytical performance, appropriateness to analyze human biological samples, including corresponding extraction and cleanup procedures, and their validation according to ISO 17025/FDA Guidance for Industry. The LC-MS/MS method showed a higher performance compared with the GC-MS method. The LC-MS/MS was more sensitive, needed a smaller sample volume (25 µL) and less chemicals, was less time consuming (cleaning up, sample preparation, and analysis), and resulted in a better LOD (<1 ng/mL)/LOQ (10 ng/mL). The calibration curve of the LC-MS/MS method (10–2000 ng/mL) showed linearity over a larger range with correlation coefficients r2 > 0.995 for all tested matrices (blood, saliva, and dialysate). For larger sample numbers as in pharmacokinetic/pharmacodynamic studies and for bedside as well as routine analyses, the LC-MS/MS method offers significant advantages over the GC-MS method.
机译:苯妥英钠(PHT)是最常用的关键剂量药物之一,如果剂量不足或过量可能会导致严重的后果,例如癫痫发作或中毒。因此,监测和精确测量患者体内PHT的浓度至关重要。这项研究开发并验证了一种LC-MS / MS方法,用于测量不同体腔(即人脑透析液,血液和唾液)中的苯妥英钠浓度,并将其与以前开发的可测量苯妥英钠中PHT的GC-MS方法进行比较。相同的生物基质。根据这两种方法的分析性能,是否适合分析人类生物样品(包括相应的提取和净化程序)以及根据ISO 17025 / FDA工业指南进行的验证,对这两种方法进行评估和比较。与GC-MS方法相比,LC-MS / MS方法显示出更高的性能。 LC-MS / MS灵敏度更高,需要的样品体积较小(25 µL)和化学物质较少,耗时较少(清理,样品制备和分析),并且LOD更好(<1µng / mL )/ LOQ(10µng / mL)。 LC-MS / MS方法的校准曲线(10–2000µng / mL)在较大范围内显示线性,所有测试基质(血液,唾液和透析液)的相关系数r2> 0.995。对于药代动力学/药效学研究中较大的样品数量以及床旁以及常规分析,LC-MS / MS方法比GC-MS方法具有明显优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号