References(25) Cited-By(1) To establish a protocol for a multi-phase computed tomography (CT) of the canine pancreas using the bolus-tracking technique, dynamic scan and multi-phase CT were performed in six normal beagle dogs. The dynamic scan was performed for 60 sec at 1-sec intervals after the injection (4 ml/sec) of a contrast medium, and intervals from aortic enhancement appearance to aortic, pancreatic parenchymal and portal vein peaks were measured. The multi-phase CT with 3 phases was performed three times using a bolus-tracking technique. Scan delays were 0, 15 and 30 in first multi-phase scan; 5, 20 and 35 in second multi-phase scan; and 10, 25 and 40 sec in third multi-phase scan, respectively. Attenuation values and contrast enhancement pattern were analyzed from the aorta, pancreas and portal vein. The intervals from aortic enhancement appearance to aortic, pancreatic parenchymal and portal vein peaks were 3.8 ± 0.7, 8.7 ± 0.9 and 13.3 ± 1.5 sec, respectively. The maximum attenuation values of the aorta, pancreatic parenchyma and portal vein were present at scan sections with no scan delay, a 5-sec delay and a 10-sec delay, respectively. When a multi-phase CT of the canine pancreas is triggered at aortic enhancement appearance using a bolus-tracking technique, the recommended optimal delay times of the arterial and pancreatic parenchymal phases are no scan delay and 5 sec, respectively.
机译:参考文献(25)(1)为了建立使用大剂量追踪技术对犬胰腺进行多相计算机断层扫描(CT)的协议,对六只正常的比格犬进行了动态扫描和多相CT。注射造影剂(4 ml / sec)后,以1秒的间隔执行动态扫描60秒,并测量从主动脉增强外观到主动脉,胰腺实质和门静脉峰值的间隔。使用大剂量追踪技术对三相进行多相CT扫描3次。第一次多相扫描的扫描延迟分别为0、15和30。 5、20和35在第二个多相扫描中;在第三次多相扫描中分别为10秒,25秒和40秒。从主动脉,胰腺和门静脉分析衰减值和对比增强模式。从主动脉强化出现到主动脉,胰实质和门静脉峰值的间隔分别为3.8±0.7、8.7±0.9和13.3±1.5秒。主动脉,胰实质和门静脉的最大衰减值分别出现在没有扫描延迟,5秒延迟和10秒延迟的扫描部分。当使用大剂量追踪技术在主动脉强化出现时触发犬胰腺的多相CT时,建议的动脉和胰腺实质期的最佳延迟时间分别为无扫描延迟和5 sec。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号