Optimal scan delay depending on contrast material injection duration in abdominal multi-phase computed tomography of pancreas and liver in normal Beagle dogs

机译:最佳扫描延迟取决于正常Beagle犬腹部多相胰腺和肝脏CT造影剂中造影剂注入的持续时间

获取原文
           

摘要

This study was conducted to establish the values for optimal fixed scan delays and diagnostic scan delays associated with the bolus-tracking technique using various contrast material injection durations in canine abdominal multi-phase computed tomography (CT). This study consisted of two experiments employing the crossover method. In experiment 1, three dynamic scans at the porta hepatis were performed using 5, 10 and 15 sec injection durations. In experiment 2, two CT scans consisting of five multi-phase series with different scan delays of 5 sec intervals for bolus-tracking were performed using 5, 10 and 15 sec injection duration. Mean arrival times to aortic enhancement peak (12.0, 15.6, and 18.6 sec for 5, 10, and 15 sec, respectively) and pancreatic parenchymal peak (17.8, 25.1, and 29.5 sec) differed among injection durations. The maximum mean attenuation values of aortas and pancreases were shown at the scan section with 0 and 5, 0 and 10 and 5 and 10 sec diagnostic scan delays during each injection duration, respectively. The optimal scan delays of the arterial and pancreatic parenchymal phase in multi-phase CT scan using fixed scan delay or bolus-tracking should be determined with consideration of the injection duration.
机译:进行这项研究的目的是在犬腹部多相计算机断层扫描(CT)中使用各种造影剂注入时间,确定与推注跟踪技术相关的最佳固定扫描延迟和诊断扫描延迟的值。这项研究包括采用交叉法的两个实验。在实验1中,使用5、10和15秒的注射时间对肝门进行了三次动态扫描。在实验2中,使用5秒,10秒和15秒的注射持续时间进行了两次CT扫描,这些扫描由五个多相序列组成,具有5秒间隔的不同扫描延迟以进行推注跟踪。在注射持续时间之间,到达主动脉增强峰的平均到达时间(分别为5、10和15秒的12.0、15.6和18.6秒)和胰腺实质峰值(17.8、25.1和29.5秒)有所不同。主动脉和胰脏的最大平均衰减值分别在每个注射期间的扫描部分显示为0和5、0和10以及5和10秒的诊断扫描延迟。在使用固定扫描延迟或推注跟踪的多相CT扫描中,动脉和胰腺实质期的最佳扫描延迟应考虑注射持续时间来确定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号