Background and purpose CT scan protocols are often created with imaging parameters set to minimize imaging dose with acceptable image quality for diagnostic purpose. This study aimed to optimize CT imaging parameters to help accurately delineate structures for radiation therapy planning and delivery guidance. Materials and methods Imaging parameters were optimized with CT data acquired for a phantom to create image quality enhancement (IQE) protocols, which were subsequently used to scan a prostate and a pancreatic cancer patient who underwent image-guided radiotherapy (IGRT). The patient images were compared with those scanned with standard clinical protocols, the quality of these images was assessed with various methods (survey, inter- and intra-observer variations, and dice coefficient analysis) for the two patient cases. Results An effective tube current–time product of ~1000?mAs was found to be a reasonable choice to balance CT quality and CT dose. With increased dose and penetration taken into account, 100 and 120?kV tube voltages were found appropriate for the IQE protocols. The inter- and intra-observer variations for the IQE data were smaller than those with the standard protocols. Dice coefficient analysis indicated that the IQE protocols lead to improved dice coefficient by as much as 8 percentage points for the two cases studied. Conclusion CT image quality can be improved with the IQE protocols created in this study, to provide better soft tissue contrast, which would be beneficial for use in radiation therapy, e.g., for planning data acquisition or for IGRT for hypo-fractionated treatments.
机译:背景和目的CT扫描协议通常是通过设置成像参数来创建的,以使成像剂量最小化,并具有可接受的图像质量以用于诊断。这项研究旨在优化CT成像参数,以帮助准确描绘出放射治疗计划和递送指导的结构。材料和方法用获取的幻象CT数据优化成像参数,以创建图像质量增强(IQE)方案,随后将其用于扫描接受影像引导放射治疗(IGRT)的前列腺癌和胰腺癌患者。将患者图像与通过标准临床协议扫描的图像进行比较,并通过两种方法(调查,观察者之间和观察者内部变异以及骰子系数分析)评估这些图像的质量。结果发现有效的管电流-时间乘积约为1000?mAs是平衡CT质量和CT剂量的合理选择。考虑到增加的剂量和穿透力,发现适用于IQE方案的100和120?kV管电压。 IQE数据在观察者之间和观察者内部的变化小于标准协议的观察者之间和内部的变化。骰子系数分析表明,对于所研究的两种情况,IQE协议可将骰子系数提高多达8个百分点。结论通过本研究中创建的IQE协议可以改善CT图像质量,以提供更好的软组织对比度,这将有利于放射治疗(例如计划数据采集或IGRT进行次分割治疗)的使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号