首页> 外文期刊>Nephro-Urology Monthly >Comparison of Body Composition Assessed by Multi-Frequency Segmental Bioelectrical Impedance Analysis and Dual Energy X-Ray Absorptiometry in Hemodialysis Patients
【24h】

Comparison of Body Composition Assessed by Multi-Frequency Segmental Bioelectrical Impedance Analysis and Dual Energy X-Ray Absorptiometry in Hemodialysis Patients

机译:血液透析患者通过多段分段生物电阻抗分析和双能X线吸收法评估身体成分的比较

获取原文
           

摘要

Background: The assessment of body composition during the course of treatment of hemodialysis patients is crucial for optimal treatment. We intended to assess the diagnostic performance of bioelectrical impedance analysis (BIA), which could be used at the bedside in dialysis wards, and compare it with the results of dual-energy X-ray absorptiometry (DEXA). Methods: In a cross-sectional study, 43 patients with end-stage renal disease (ESRD) after hemodialysis sessions underwent direct segmental multi-frequency BIA. Volume status and body composition indices with eight electrodes connected to four limbs were measured at 1, 5, 50, 250, 500, and 1000 kHz frequencies. Then, the patients were sent to the nuclear ward for the corresponding assessments by DEXA. The results of the two methods were compared by a paired t-test and the correlations were assessed using general linear models and regression analyses. For the assessment of agreements, Bald-Altman plots were used. Results: The whole body values for bone, fat, and lean body mass were different between BIA (3.4, 22, and 44.5 kg, respectively) and DEXA (1.5, 28.5, and 40.4 kg, respectively). However, the results were strongly linearly correlated even after adjustment for age and sex (r = 0.67, P = 0.001 for bone mass; r = 0.93, P = 0.001 for fat mass; and r = 0.96, P = 0.001 for lean body mass). The same strong correlation was found for the segmental values. Conclusions: The results of BIA and DEXA are correlated strongly and are interchangeable. As the BIA is more easily available and less expensive, the routine use of BIA at hemodialysis departments is reasonable.
机译:背景:在血液透析患者的治疗过程中,对身体成分的评估对于最佳治疗至关重要。我们打算评估生物电阻抗分析(BIA)的诊断性能,该诊断性能可在透析病床的床边使用,并将其与双能X射线吸收法(DEXA)的结果进行比较。方法:在一项横断面研究中,对43名血液透析结束后的终末期肾病(ESRD)患者进行了直接分段多频BIA。在1、5、50、250、500和1000 kHz频率下测量了八个电极连接到四个肢体的体积状态和身体成分指数。然后,患者被DEXA送到核病房进行相应评估。通过配对t检验比较了两种方法的结果,并使用通用线性模型和回归分析评估了相关性。为了评估协议,使用了Bald-Altman图。结果:BIA(分别为3.4、22和44.5 kg)和DEXA(分别为1.5、28.5和40.4 kg)之间的全身骨骼,脂肪和瘦体重值有所不同。但是,即使在校正了年龄和性别之后,结果仍具有很强的线性相关性(r = 0.67,P = 0.001(骨量); r = 0.93,P = 0.001(脂肪量); r = 0.96,P = 0.001(瘦体重) )。对于分段值发现了相同的强相关性。结论:BIA和DEXA的结果密切相关并且可以互换。由于BIA更容易获得且更便宜,因此在血液透析部门常规使用BIA是合理的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号