Effect of nitrous oxide on bispectral index values at equi-minimum alveolar concentrations of sevoflurane and desflurane

机译:一氧化二氮对七氟醚和地氟醚等最小肺泡浓度下双光谱指数值的影响

获取原文
       

摘要

Background and Aims: Bispectral index (BIS) values may be anaesthetic agent-specific, depending on their ability to suppress the electroencephalogram (EEG) signals. We carried out a prospective, randomised clinical trial to study the effect of nitrous oxide (N2O) on the BIS values at an equi-minimum alveolar concentration (MAC) of sevoflurane and desflurane. Methods: Sixty adult patients undergoing spine surgery were randomised into two groups; Group S (sevoflurane; n = 30) and Group D (desflurane; n = 30) for the maintenance of anaesthesia in oxygen and air or oxygen and N2O mixture (FiO2-0.4) (Stage 1). BIS and fraction of inspired and end-tidal concentration of agents were noted at 1.0 MAC. In Stage 2, air or N2O was discontinued and the other carrier gas was introduced. At steady state of this carrier gas, values were again noted as in Stage 1. Statistical analysis was performed using two-way analysis of variance followed by Bonferroni correction, and Student's t-test for paired data. PResults: With air-oxygen as the carrier gas, sevoflurane and desflurane resulted in comparable BIS values (P = 0.44). With addition of 60% N2O, there was a significant increase in BIS values at 1.0 MAC for both the agents. Furthermore, higher BIS values were observed with sevoflurane compared to desflurane (P = 0.01). Conclusion: Sevoflurane and desflurane at equi-MAC concentration exert similar effect on BIS values when used with air-oxygen. N2O results in higher BIS values; this effect is more pronounced in combination with sevoflurane.
机译:背景和目的:双谱指数(BIS)值可能是麻醉剂特异性的,具体取决于它们抑制脑电图(EEG)信号的能力。我们进行了一项前瞻性随机临床试验,以研究七氟醚和地氟醚的最小肺泡浓度(MAC)时一氧化二氮(N 2 O)对BIS值的影响。方法:将60例接受脊柱外科手术的成年患者随机分为两组。 S组(七氟醚; n = 30)和D组(地氟醚; n = 30),用于维持氧气,空气或氧气和N 2 O混合物(FiO 2 -0.4)(阶段1)。在1.0 MAC处记录BIS以及病原体的吸气和潮气末浓度。在阶段2中,停止使用空气或N 2 O,并引入其他载气。在此载气的稳定状态下,再次如阶段1所示记录值。使用双向方差分析,Bonferroni校正和成对数据的Student t检验进行统计分析。 P结果:以空气氧气为载气,七氟醚和地氟醚的BIS值相当(P = 0.44)。通过添加60%N 2 O,两种试剂的BIS值在1.0 MAC处均显着增加。此外,与地氟醚相比,七氟醚的BIS值更高(P = 0.01)。结论:当与空气氧气一起使用时,等MAC浓度的七氟醚和地氟醚对BIS值的作用相似。 N 2 O导致更高的BIS值;与七氟醚组合使用时,这种作用更为明显。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号