The polarographic reduction of tin gives rise to an additional peak at more positive potentials than tin in the presence of selenite. It is found that when the selenite concentration exceeded the tin concentration, only one peak for tin was observed, enabling the determination of both these ions. A procedure for the direct determination of trace amounts of tin by the addition of selenite is described. It was possible to determine trace amounts of tin and selenium using this peak. Tin and selenium in a synthetic sample at 5 × 10-6 M Sn(II) and 2.5 × 10-6 M Se(IV) concentrations could be determined with -6.0% and -8.0% relative errors, respectively. This procedure was applied to canned corn, and 5.95 ± 0.54 µg/g tin could be determined with a 9.1% relative standard deviation.
机译:锡的极谱还原法在存在亚硒酸盐时比锡具有更多的正电位。发现当亚硒酸盐浓度超过锡浓度时,仅观察到锡的一个峰,从而能够确定这两个离子。描述了通过添加亚硒酸盐直接测定痕量锡的方法。使用该峰可以测定痕量的锡和硒。合成样品中锡和硒的浓度分别为5×10-6 M Sn(II)和2.5×10-6 M Se(IV),相对误差分别为-6.0%和-8.0%。该程序应用于玉米罐头,可以测定出5.95±0.54 µg / g锡,相对标准偏差为9.1%。