A novel, sensitive and specific screening method for trace multi-residues of 13 ?2-agonists in porcine urine by combining atmospheric solid analysis probe (ASAP) source with tandem mass spectrometry (MS/MS) has been developed. Optimization experiments were carried out including the selection of solvent, probe temperature and monitoring ionic pairs. Using ASAP combined with rapid solid-phase extraction (SPE) procedures, not only the matrix interference of porcine urine was decreased, but also the sensitivity of the method was improved. Under the optimal conditions, the performance of the proposed method was studied. The linear correlation coefficients (R2) of calibration curves for 13 ?2-agonists were above 0.98 in the concentration range of 0.5 ng mLa?’1 to 300 ng mLa?’1. The limits of determination (LOD) for all target compounds were below 0.20 ng mLa?’1, recoveries of the developed method for different spiked concentrations varied from 58.5 to 85.7%. A single run for the analysis of 13 ?2-agonists in a urine sample was achieved within 1.0 min for ASAP-MS/MS detection. In addition to the fast analysis speed, MS/MS provided structural information for the confirmation of target analytes. Real porcine urine samples were investigated and the results were in accordance with the confirmatory determination results by using Chinaa€?s agricultural industry standard method. The developed method can potentially be used for the screening of 13 ?2-agonists in porcine urine for the surveillance of livestock.
机译:通过结合大气固体分析探针(ASAP)源和串联质谱(MS / MS),开发了一种新颖,灵敏,特异的猪尿中13β2-激动剂痕量多残留筛选方法。进行了优化实验,包括溶剂的选择,探针温度和监测离子对。通过ASAP与快速固相萃取(SPE)程序相结合,不仅减少了猪尿液对基质的干扰,而且提高了该方法的灵敏度。在最佳条件下,研究了该方法的性能。在0.5 ng mLa?1至300 ng mLa?1的浓度范围内,13种α2-激动剂的校准曲线的线性相关系数(R2)高于0.98。所有目标化合物的测定极限(LOD)均低于0.20 ng mLa?1,所开发方法的不同加标浓度的回收率从58.5至85.7%不等。用于ASAP-MS / MS检测的1.0分钟内即可完成一次尿液样品中13种β2-激动剂的分析。除了快速的分析速度外,MS / MS还提供了用于确认目标分析物的结构信息。使用中国农业工业标准方法对真实的猪尿液样本进行了调查,结果与确定的测定结果相符。所开发的方法可潜在地用于筛选猪尿液中的13β2-激动剂以监测家畜。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号