首页> 外文OA文献 >Automated and sensitive determination of four anabolic androgenic steroids in urine by online turbulent flow solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry: A novel approach for clinical monitoring and doping control
【2h】

Automated and sensitive determination of four anabolic androgenic steroids in urine by online turbulent flow solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry: A novel approach for clinical monitoring and doping control

机译:在线湍流固相萃取-液相色谱-串联质谱法自动灵敏地测定尿液中四种合成代谢雄激素类固醇:临床监测和兴奋剂控制的新方法

摘要

A novel method for automated and sensitive analysis of testosterone, androstenedione, methyltestosterone and methenolone in urine samples by online turbulent flow solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry was developed. The optimization and validation of the method were discussed in detail. The Turboflow C18-P SPE column showed the best extraction efficiency for all the analytes. Nanogram per liter (ng/L) level of MS could be determined directly and the limits of quantification (LOQs) were 0.01 ng/mL, which were much lower than normally concerned concentrations for these typical anabolic androgenic steroids (AAS) (0.1 ng/mL). The linearity range was from the LOQ to 100 ng/mL for each compound, with the coefficients of determination (r(2)) ranging from 0.9990 to 0.9999. The intraday and interday relative standard deviations (RSDs) ranged from 1.1% to 14.5% (n=5). The proposed method was successfully applied to the analysis of urine samples collected from 24 male athletes and 15 patients of prostate cancer. The proposed method provides an alternative practical way to rapidly determine MS in urine samples, especially for clinical monitoring and doping control. (C) 2014 Elsevier B.V. All rights reserved.
机译:建立了在线湍流固相萃取-高效液相色谱-串联质谱联用技术自动,灵敏地分析尿液中睾丸激素,雄烯二酮,甲基睾丸酮和美沙酮的新方法。详细讨论了该方法的优化和验证。 Turboflow C18-P SPE色谱柱对所有分析物均显示出最佳的萃取效率。可以直接确定每升(ng / L)MS的纳克级水平,定量限(LOQs)为0.01 ng / mL,远低于这些典型的合成代谢雄性类固醇(AAS)的正常浓度(0.1 ng / L)。毫升)。每种化合物的线性范围为LOQ至100 ng / mL,测定系数(r(2))为0.9990至0.9999。日内和日间相对标准偏差(RSD)在1.1%至14.5%之间(n = 5)。所提出的方法已成功地用于分析从24位男运动员和15位前列腺癌患者中收集的尿液样品。所提出的方法提供了另一种实用的方法,可快速测定尿样中的MS,尤其是用于临床监测和兴奋剂控制。 (C)2014 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号