首页> 外文期刊>Chemical science >Matrix coating assisted by an electric field (MCAEF) for enhanced tissue imaging by MALDI-MS
【24h】

Matrix coating assisted by an electric field (MCAEF) for enhanced tissue imaging by MALDI-MS

机译:电场(MCAEF)辅助的基质涂层,可通过MALDI-MS增强组织成像

获取原文
           

摘要

A novel technique, termed matrix coating assisted by an electric field (MCAEF), for enhancing tissue imaging by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was developed in this study. In this technique a static and uniform electric field is applied to sliced tissue sections during matrix spray-coating, resulting in the enrichment of positively or negatively chargeable analytes in the MALDI matrix layer. Experimental results show that MCAEF not only increased the sensitivity of lipid and protein detection across the board in the subsequent MALDI-MS analyses, but also resulted in successful imaging of a larger number of analytes. MALDI imaging enhancement with MCAEF was observed for various tissues (rat liver, rat brain, and porcine adrenal gland) and with different MALDI matrices (e.g., quercetin, 2-mercaptobenzothiazole, dithranol, 9-aminoacridine, and sinapinic acid) and the sensitivity increases were independent of the solvent compositions and pH values of the matrix solutions. Taking rat brain as an example, MCAEF led to the on-tissue detection and imaging of 648 identified lipids by combining positive and negative ion detection by MALDI-Fourier transform ion cyclotron resonance MS and with quercetin as the matrix, as compared to only 344 lipids without MCAEF. For protein imaging, up to 232 protein signals were successfully detected in rat brain tissue sections by MALDI-time-of-flight MS within a mass range of 3500 to 37?000 Da, as compared to 119 without MCAEF. MCAEF also enabled the detection of higher molecular-weight proteins. These results demonstrate the advantages of MCAEF for overall performance improvements in MALDI imaging and we believe that this technique has the potential to become a standard practice for MALDI tissue imaging.
机译:在这项研究中,开发了一种新技术,称为电场辅助基质涂层(MCAEF),用于通过基质辅助激光解吸/电离质谱(MALDI-MS)增强组织成像。在该技术中,在基质喷涂过程中,将均匀且均匀的电场施加到切片的组织切片上,从而使MALDI基质层中带正电荷或负电荷的分析物富集。实验结果表明,MCAEF不仅可以在后续的MALDI-MS分析中全面提高脂质和蛋白质检测的灵敏度,而且还可以成功地对大量分析物进行成像。在各种组织(大鼠肝,大鼠脑和猪肾上腺)和不同的MALDI基质(例如,槲皮素,2-巯基苯并噻唑,二苏醇,9-氨基ac啶和芥子酸)和灵敏度的增加与基质溶液的溶剂组成和pH值无关。以大鼠大脑为例,MCAEF通过结合使用MALDI-Fourier变换离子回旋共振MS和以槲皮素为基质的正离子和负离子检测,从而对648种脂类进行了组织检测和成像,而只有344种脂类没有MCAEF。对于蛋白质成像,通过MALDI飞行时间质谱仪可在3500至37?000 Da的质量范围内成功地在大鼠脑组织切片中成功检测到232个蛋白质信号,而没有MCAEF的则为119。 MCAEF还可以检测更高分子量的蛋白质。这些结果证明了MCAEF可以改善MALDI成像的整体性能,并且我们认为该技术有可能成为MALDI组织成像的标准做法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号