首页> 外文期刊>Dental materials >On the effect of an internal light conductor on the marginal integrity of class-Ⅱ composite fillings
【24h】

On the effect of an internal light conductor on the marginal integrity of class-Ⅱ composite fillings

机译:内部光导体对Ⅱ类复合填料边缘完整性的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives. The aim of this study was to examine the marginal behavior of class-Ⅱ double surface fillings made with newly designed light transmitting inserts. These inserts guide the polymerization light directly into the body of the filling. Material and methods. Sixty standardized two-surface cavities have been prepared into freshly extracted human molars and filled with Herculite XRV. Fifteen cavities were filled using the incremental technique (positive control group), 15 were filled with one single increment (negative control group) and 15 teeth each were filled with light conducting inserts with and without use of the light conducting system. Before and after thermomechanical stressing in a chewing simulator (50,000 x 50N and 2000 cycles between 5℃ and 55℃), the amount of perfect margin was measured by quantitative margin analysis using a SEM. Additionally, following dye penetration (24h, 0.1% methylene blue), all teeth were cut in the mesio-distal direction and the amount of penetration was measured. Results. The group with light transmitting inserts showed 79.8% perfect margin, the positive control group 68.0%, the group with inactive inserts 65.4% and the negative control group 57.8%. MANOVA showed a strong effect (p < 0.001) on the parameters group and thermocy-cling. The results from dye penetration were similar. Significance. Light conducting inserts seem to have a positive effect on the marginal integrity of class-Ⅱ composite fillings. Results show that this effect is produced by the internal light conductor and not volumetric effect alone.
机译:目标。这项研究的目的是研究用新设计的透光插入物制成的Ⅱ类双面填充物的边缘行为。这些插入物将聚合光直接导入填充物主体。材料与方法。已经在新鲜提取的人类臼齿中制备了60个标准化的两面型腔,并填充了Herculite XRV。使用增量技术填充15个腔(阳性对照组),以单个增量填充15个腔(阴性对照组),并且在使用和不使用导光系统的情况下,每个15颗牙齿均填充有导光刀片。在咀嚼模拟器中进行热机械应力之前和之后(50,000 x 50N和5℃至55℃之间的2000个循环),通过使用SEM进行定量余量分析来测量完美余量的量。另外,在染料渗透(24h,0.1%亚甲蓝)之后,在近中方向上切开所有牙齿,并测量渗透量。结果。带有透光插入物的组显示出完美边缘的79.8%,阳性对照组为68.0%,不活动插入物的组为65.4%,阴性对照组为57.8%。 MANOVA在参数组和热循环方面显示出强大的效果(p <0.001)。染料渗透的结果相似。意义。导电插件似乎对Ⅱ类复合填料的边缘完整性有积极的影响。结果表明,这种效应是由内部光导体产生的,而不是单独的体积效应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号