In this paper the problem of finding the best performing base isolator parameters of a seismic excited structure is treated. The structural and earthquake parameters and the isolator type are considered assigned. The approach here proposed is based on the minimization of the power flow transmitted by the isolator to the structure. The power flow is a statistical measure of the power transmitted to the structure during an earthquake. The earthquake is idealized as a filtered stochastic process. This approach considers the structure-isolator-excitation system as a super-structure in which the structure, the isolator and the excitation filter are the sub-structures. It guarantees a very good global behaviour of the structure, both in terms of relative displacements and in terms of accelerations. The isolator types considered in this work are the linear, the yielding and the friction ones.
机译:在本文中,解决了寻找地震激励结构的最佳性能基础隔离器参数的问题。结构和地震参数以及隔离器类型均视为已分配。这里提出的方法基于最小化由隔离器传输到结构的功率流。潮流是地震期间传递到建筑物的电能的统计量度。地震被理想化为经过过滤的随机过程。该方法将结构-隔离器-激励系统视为超结构,其中结构,隔离器和激励滤波器是子结构。无论是相对位移还是加速度,它都保证了结构的良好整体性能。在这项工作中考虑的隔离器类型是线性的,屈服的和摩擦的。