...
首页> 外文期刊>Computer methods in biomechanics and bio >Relative accuracy of spin-image-based registration of partial capitate bones in 4DCT of the wrist
【24h】

Relative accuracy of spin-image-based registration of partial capitate bones in 4DCT of the wrist

机译:手腕4DCT中基于旋转图像的部分头状骨的相对准确性

获取原文
获取原文并翻译 | 示例
           

摘要

In image-based biomechanical analyses, registration transformations are the data of interest. In dynamic four-dimensional computed tomography (4DCT) imaging, the capitate is often partially imaged. While alignment of incomplete objects poses a significant registration challenge, the established spin-image surface-matching algorithm can be utilised to align two surfaces representing disparate but overlapping portions of an object. For this reason, the spin-image algorithm was chosen for the registration of partial bone geometry in 4DCT of the wrist. Registrations were performed on 11 4DCT datasets using complete and partial capitate meshes generated by cropping complete meshes. Relative accuracy was assessed as the difference between partial- and complete-geometry registrations. Accurate registration of partial capitate geometry was achieved with 55% of the proximal capitate geometry on average, and in some cases as little as 35%. Requisite geometry depends on feature salience and imaging resolution; however, the spin-image algorithm should be considered a valuable tool for biomechanists and image analysts.
机译:在基于图像的生物力学分析中,配准转换是感兴趣的数据。在动态四维计算机断层扫描(4DCT)成像中,人头通常是部分成像的。尽管不完整物体的对准带来了巨大的配准挑战,但已建立的自旋图像表面匹配算法可用于对准代表物体不同但重叠部分的两个表面。因此,选择了旋转图像算法来记录手腕的4DCT中部分骨骼的几何形状。使用通过裁剪完整网格生成的完整和部分头状网格对11个4DCT数据集进行配准。相对精度被评估为部分几何配准和完整几何配准之间的差异。平均平均近端头状部几何形状的55%可以准确记录部分头状部几何形状,在某些情况下仅为35%。所需的几何形状取决于特征的显着性和成像分辨率;但是,自旋图像算法应被视为对生物力学和图像分析人员有价值的工具。

著录项

  • 来源
    《Computer methods in biomechanics and bio》 |2016年第6期|360-367|共8页
  • 作者单位

    Division of Orthopedic Research, Biomechanics Laboratory, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA;

    Biomedical Imaging Resource, Mayo Clinic College of Medicine, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA;

    Department of Radiology, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA;

    Division of Orthopedic Research, Biomechanics Laboratory, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA;

    Department of Radiology, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA;

    Rehabilitation Medicine Research Center, Physical Medicine and Rehabilitation, Mayo Clinic, 200 First St. SW, Rochester, MN 55905, USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    wrist; 4DCT; registration; spin-image; surface matching;

    机译:腕;4DCT;注册;自旋图像表面匹配;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号