首页> 外文期刊>IEEE Transactions on Components and Packaging Technologies >Mitigation of Connector Damage During Disengaging DC Loads Using Polymeric Arc Suppressor
【24h】

Mitigation of Connector Damage During Disengaging DC Loads Using Polymeric Arc Suppressor

机译:使用聚合电弧抑制器减轻直流负载脱离过程中连接器的损坏

获取原文
获取原文并翻译 | 示例

摘要

Although connectors are generally not designed to disconnect electrical loads under power, in some circumstances they are mated and unmated under load. For instance, during repairs, diagnostic procedures, or when blown fuses are replaced under short circuit conditions. At dc system voltage levels significantly higher than the minimum arc voltage of metals such hot-disconnections may impact the reliability of the connection, the electrical distribution system, and automotive safety. Gassing polymers mounted onto connector terminals may reduce the damage resulting from disconnections under dc loads, and therefore enable connector designs with occasionally (forward running) arcing terminals. The authors discuss the effects of different types of gassing polymers on arc extinction and connector damage of standard automotive connectors.
机译:尽管通常不将连接器设计为在通电状态下断开电气负载,但在某些情况下,它们在负载下会配对并取消配对。例如,在维修,诊断过程中或在短路情况下更换熔断的保险丝时。在直流系统电压水平明显高于金属的最小电弧电压的情况下,这种热断开可能会影响连接的可靠性,配电系统和汽车安全性。安装在连接器端子上的含气聚合物可以减少直流负载下断开连接所造成的损坏,因此可以使连接器设计偶尔具有(向前运行)电弧端子。作者讨论了不同类型的放气聚合物对标准汽车连接器的灭弧和连接器损坏的影响。