A semi-automated method for measuring femoral shape to derive version and its comparison with existing methods

机译:一种测量股骨形态的半自动方法及其与现有方法的比较

获取原文
获取原文并翻译 | 示例

摘要

The measurement of femoral version is important in surgical planning of derotational osteotomies particularly for patients with proximal femoral deformity. It is, however, difficult to measure version accurately and differences of 10° to 15° have been found between repeated measurements. The aim of this work was first to develop a method of measuring femoral version angle where the definition of the neck axis is based on the three-dimensional point cloud making up the neck, second to automate many of the processes involved thus reducing the influence of human error and third to ensure the method could run on freely available software suitable for most computer platforms. A CT scan was performed on 44 cadaveric femurs to generate point clouds of the femoral surfaces. The point clouds were then analysed semi-automatically to determine femoral version angle between a neck axis defined by the bone surface points belonging only to the neck and a femoral condylar axis. The results from the neck fitting method were compared against three other methods typically used in the clinic (Murphy, Reikeras and Lee methods). Version angle measured by the new method gave 19.1° ± 7.3° (mean ± standard deviation) for the set of cadaveric femurs, 3.5° lower than the Murphy method and 6.8° and 11.0° higher than the Reikeras and Lee 2D methods respectively. The results demonstrate a method of measuring femoral version angle incorporating a high level of automation running on free software.
机译:股骨版本的测量对于旋转性截骨术的手术计划非常重要,特别是对于股骨近端畸形的患者。但是,很难精确测量版本,并且在重复测量之间发现10°至15°的差异。这项工作的目的是首先开发一种测量股骨屈曲角度的方法,其中颈部轴的定义基于构成颈部的三维点云,其次要使许多相关过程自动化,从而减少股骨颈角的影响。人为错误和第三点,以确保该方法可以在适用于大多数计算机平台的免费软件上运行。对44个尸体股骨进行了CT扫描以生成股骨表面的点云。然后半自动分析点云,以确定仅属于颈部的骨表面点定义的颈部轴与股骨con轴之间的股骨翻角。将颈部贴合方法的结果与临床上通常使用的其他三种方法(Murphy,Reikeras和Lee方法)进行了比较。通过新方法测量的倾斜角度使尸体股骨组的角度为19.1°±7.3°(平均值±标准差),分别比Murphy方法低3.5°和比Reikeras和Lee 2D方法高6.8°和11.0°。结果证明了一种结合了在免费软件上运行的高度自动化的测量股骨翻角的方法。

著录项

  • 来源
    《Communications in Numerical Methods in Engineering》 |2014年第11期|1314-1325|共12页
  • 作者单位

    Research & Teaching Centre, Royal Orthopaedic Hospital, Bristol Road South, Northfield, Birmingham, B3I 2AP, UK;

    Research & Teaching Centre, Royal Orthopaedic Hospital, Bristol Road South, Northfield, Birmingham, B3I 2AP, UK;

    Research & Teaching Centre, Royal Orthopaedic Hospital, Bristol Road South, Northfield, Birmingham, B3I 2AP, UK;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    femoral neck version angle; 3D measurement; CT;

    机译:股骨颈型角;3D测量电脑断层扫描;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号